35
SET
LIMIT
LEARN
TRANSMITTER
1
ON
2 3 4 5 6 7
MODES
ON
OFF
1 2 3 4 5 6 7
1
ON
2 3 4
DUAL
MODES
ON
OFF
1 2 3 4
1
ON
2 3 4
DUAL
MODES
ON
OFF
1 2 3 4
STALL FORCE
MI
N
MA
X
GRN
BLK
RED
RECEIVER
COM
COM
CYCLE
CLOSE
SAFETY
EXI
T
OPEN
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
J11
J8
J12
Step 3
• IF the MASTER gate was the first gate to reach the opened position: set the number 4 DIP switch of the DUAL MODES
switches on the control board to the OFF position. Then press and hold the SET LIMIT button for five seconds.
• IF the SLAVE gate was the first gate to reach the opened position: set the number 4 DIP switch of the DUAL MODES
switches to the ON position. Then press and hold the SET LIMIT button for five seconds.
Step 4
Press the transmitter button and allow the gates to return to the closed
position. YOUR FIRST GATE’S OPEN POSITION LIMIT IS NOW
PROGRAMMED.
Step 5
Activate your openers again by pressing the entry transmitter button. Your
gates should now be moving from the closed positions toward their open
positions. The first gate will stop at the spot you just programmed and the
second gate will continue to open until you press the transmitter button again.
Press the transmitter button when the second gate reaches the desired open
position. This step may be repeated until desired open position is achieved.
Once the desired OPEN position has been achieved, proceed to step 6.
Step 6
• IF the MASTER gate was the second gate to reach the opened position: set
the number 4 DIP switch of the DUAL MODES switches on the control
board to the OFF position. Then press and hold the SET LIMIT button for
five seconds.
• IF the SLAVE gate was the second gate to reach the opened position: set
the number 4 DIP switch of the DUAL MODES switches to the ON position. Then press and hold the SET LIMIT button
for five seconds.
Step 7
Press the transmitter button and allow the gates to return to the closed position. BOTH YOUR MASTER AND SLAVE
GATE’S OPEN POSITION LIMITS ARE NOW PROGRAMMED.
TESTING YOUR OPEN LIMIT SETTING:
Press your entry transmitter and allow your gates to open. If OPEN positions are not correct or need to be changed, you will
need to CLEAR your OPEN LIMIT settings and follow steps one (1) to seven (7) again.
CLEARING THE PROGRAMMED OPEN LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their closed
positions, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the open limit
positions. Follow steps one (1) to seven (7) again.