37
The Gate CLOSES Then Opens Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
3. Check the position of the stroke adjustment knob.
The Gate OPENS Then Closes Again on its Own:
1. Check the position of the mounting brackets and readjust if necessary.
2. Check the gate for binding or hinge damage.
3. Check the position of the stroke adjustment knob.
The
GTO, Inc. Technical Service Department
is open
Monday – Friday 8:00
A.M.
– 5:00
P.M.
(Eastern Time)
Telephone (800) 543-1236
Telephone (850) 575-4144
VOLTAGE RATINGS
If the Operator is Working
18 Vac Transformer ___________________________18.0 to 22.0 Vac
5 W Solar panel (single) _______________________18.0 to 22.0 Vdc 300 mA
measure voltage at panel and control box.
12 V Battery ________________________________12.0 to 13.5 Vdc 7.0 Ah
Charging circuit _____________________________12.0 to 14.8 Vdc
measure voltage with battery connected