17
CONTROL BOARD SETTINGS
THESE SETTINGS SHOULD BE ADJUSTED ONLY BY AN EXPERIENCED INSTALLER OR TECHNICIAN!
RST/LEARN:
1)
Use to set transmitter code in control board memory.
2) Press this button to clear the diagnostic and error LEDs.
DIP switches
(To change these settings, you must turn power OFF; move
the switch; then turn power back ON.)
SWNG/SLD (swing or slide gate operation): SWNG = swing gate SLD = slide
gate [factory default is SWNG].
MAST/SLV (master or slave unit): The DIP switch must be set to MAST
(OFF) for single gate applications. For dual gate applications set one control
board to MAST and the other to SLV [factory default is MAST]. See Installing
a Dual System on pages 22-23.
GATE R/L (gate closes to the right or left): The direction a gate closes is
determined by standing inside the property and facing toward the gate. Set the
DIP switch to R (OFF) for a gate that closes to the right. Set the DIP switch to
L (ON) for a gate that closes to the left.
SEQUENCE 1: This DIP switch is used for sequencing swing gates [factory default is OFF]. For single gate
applications this switch MUST be set to OFF.
SEQUENCE 2: Same as SEQUENCE 1 above.
TMR. OFF/ON (auto-close timer OFF or ON; close timer is set to 1 second at the factory): When this DIP switch is
set to ON, the CLOSE TIMER potentiometer must be adjusted [factory default is OFF].
Potentiometers
(All potentiometers are set to MIN at the factory. The size and type of gate
installation must be accommodated by adjusting the potentiometers. HOWEVER–potentiometer
settings should not be used to compensate for worn, damaged, or incorrect gate hardware.)
CLS. SENS. (closing sensitivity): Adjusts obstruction sensitivity of the gate in closing mode. The
MIN setting is for minimum gate force. The MAX setting is for maximum gate force (i.e., the
operator will require greater resistance before obstructing).
OPN. SENS. (opening sensitivity): Adjusts obstruction sensitivity of the gate in opening mode (see
CLS. SENS. above).
INERTIA: Fine tunes the operator obstruction settings in the open and close modes. This
potentiometer can be adjusted to allow the operator to push an obstruction a maximum of 2 seconds
above set obstruction levels before shutting down.
CLOSE TIMER: Controls the auto-close feature (factory
default is 1 s). It is disabled and enabled with the TMR. OFF/
ON DIP switch (see DIP switches above). The potentiometer
adjusts the amount of time the gate will remain open before
it closes. The limits are 1 to 120 seconds.
Diagnostic LEDs
(Press RST / LEARN to clear these LEDs)
PWR OK: Power (115 Vac) is being delivered to the unit.
This light will not be on when the operator is in “LEARN” mode and will
PULSE when the system is on battery backup..
TIMER ON: The auto-close timer has been enabled.
OBSTRUCT: An obstruction has been encountered.
MAX TIME: Indicates operator ran longer than
60 seconds without reaching a limit switch and the motor has shut OFF.
MIN
MAX
CLS. SENS.
MIN
MAX
OPN. SENS.
MIN
MAX
INERTIA
1
120
60
CLOSE TIMER
Potentiometers
PWR OK
TIMER ON
OBSTRUCT
MAX TIME
SENSOR ERR.
LIM SW ERR.
OPEN MTR.
INTERN.ERR.
Diagnostic LEDs
123456
ON
SWNG/SLD
MAST/SLV
GATE R/L
SEQUENC 1
SEQUENCE 2
TMR. OFF/ON
EDGE 6
EDGE 5
ST / LEARN
DIP switches