23
NOTE: A separate gate or entrance must be installed for pedestrian use.
The DUAL GATE INTERFACE RX TX terminal requires 22 AWG direct burial wire manufactured
by Belden Inc. BELDEN WIRE
®
is the ONLY wire compatible with this terminal. If another
manufacturer’s wire is connected, the DUAL GATE INTERFACE terminal will NOT FUNCTION!
BELDEN WIRE
®
must be run through its own PVC conduit to protect it from damage. BELDEN
WIRE
®
should NEVER be run in conduit containing ac wiring!
All four (4) connectors plus one (1) COMMON must be wired.
DUAL
GATE
INTER-
FACE
RX
COM
COM
TX
G
R
B
GTO
RCVR.
–
+
–
+
TB3
TB2
DUAL
GATE
INTER-
FACE
RX
COM
COM
TX
G
R
B
GTO
RCVR.
–
+
–
+
TB3
TB2
Dual Gate Interface
Auxiliary Control Board
(SLV)
Master Control Board
(MAST)
Use 22 AWG (minimum)
individually shielded
paired direct burial wire
manufactured by Belden
Inc. to connect the two
units.
123456
ON
SWNG/SLD
MAST/SLV
GATE R/L
SEQUENC 1
SEQUENCE 2
TMR. OFF/ON
EDGE 6
EDGE 5
ST / LEARN
Set DIP Switches for Swing Gates
Set
MAST/SLV
switch on each operator –
one for master and the other for slave
Set
GATE R/L
switch on each operator –
R
for the gate that closes to the right
L
for the gate that closes to the left
GND
GND
ONLY BELDEN® type 8723,
22 AWG 2-pair shielded
(w/ one ground) wire is compatible
with the DUAL GATE INTERFACE
TERMINAL.
(Ground wire is unshielded [bare]).