Wire from
Automatic GTO Lock
GTO Lock:
For use exclusively with GTO Lock (FM143 or FM144).
Connecting other devices to these terminals may cause incorrect
operation and void your warranty. You do not use the lock board
with this control board.
GTO Lock Connection:
Connect the red and black leads from the lock to the GTO LOCK
terminal on the GTO/PRO
®
2000XL control board.
Connecting GTO Automatic Gate Lock
If not connecting gate lock skip to next section.
Connecting Other Auxiliary Devices (Mag Locks,
Sirens, Lights, etc.}
• These 2 terminals are normally open 'dry-contact' (no voltage) relay ouput.
• These 2 terminals are ON (shorted) whenever the gate is moving and OFF (opened) otherwise.
• These 2 terminals maximum rating is 24Vdc, Amp.