29
Connecting Accessories
Cycle Input
The GTO/PRO® SW-2500 can accept NORMALLY OPEN, DRY-CONTACT accessories, such as; Push Button Entry Devic-
es and Key Pads.
Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.
Make sure the power to the opener is turned off
before connecting cycle input device wiring to
the terminal blocks. Unplugging the transformer
does not turn power to the opener OFF.
Cycle Input Connection:
Connect one of the accessory wires to the
COMMON
(COM)
terminal and the other to the
CYCLE
terminal on the GTO/PRO® SW-2500 control board.
Each activation of the accessory will cause the
gate to cycle as follows:
OPEN STOP CLOSE STOP
If not connecting accessories skip to next section.
Wire from Accessory
(push button, key pad, etc.)
RECEIVER
ALM
GTO RCVR.
BLK
C
O
M
GRN
BLK
RE
D
CY
CLE
SAFE
T
Y
EXI
T
SH
A
D
O
W
OPEN EDGE
C
O
M
CONTROL INPUTS
CL
OS
E
EDGE
Free Exit Input
The GTO/PRO® SW-2500 can accept NORMALLY OPEN,
DRY-CONTACT free exit/entry devices such as GTO Wand
and Loop Detector
Refer to the sensor manufacturer’s instructions for
information about installing these devices on a
vehicular gate.
Make sure the power to the opener is turned off
before connecting safety device wiring to the
terminal blocks. Unplugging the transformer
does not turn power to the opener OFF.
Free Exit Connection:
Connect Exit Wand
BLK
wire to the
COMMON (COM)
terminal and the Exit Wand
BLU
wire to the
EXIT
terminal on the GTO/PRO® SW-2500 control board.
Activation of this input will cause the gate to
open to the fully opened position. As long as
contact is held, the gate will remain open.
Wire from Exit/Entry Device
(GTO Wand, Loop Detector etc.)
RECEIVER
ALM
GTO RCVR.
BLK
C
O
M
GRN
BLK
RE
D
CY
CLE
SAFE
T
Y
EXI
T
SH
A
D
O
W
OPEN EDGE
C
O
M
CONTROL INPUTS
CL
OS
E