or Exchange the frequency form channel 3 to the present (Searching channel) 

 

                         

 

I

  is the ON/OFF key for radio and CD

and it is only available in the status of power on. The 

first pressing 

  is turning on the radio

the second pressing

 

  will turn off the radio and turn 

on the CD at the same time

and the third pressing

 

will turn off the radio and CD simultaneous

 

Ⅱ、

LCD will show present frequency and volume of the radio after turning on the radio

 

Ⅲ、

In the working of radio, the present radio frequency

 

can be changed by pressing

 

MIN

and 

HOUR

 

Ⅳ、

Pressing the key

 “

SET

  will take out the memorized radio frequency

Pressing the key

 

SET

  continually  will take out the memorized radio frequency from  channels  will  be saved at present 

channel by pressing this key continually

If none of the channel

  LCD will display 

---

 

Ⅴ、

Press  the  key

 “

MEM

 ”

  could  memorize  the  present  radio  frequency

  Pressing  the  key

 

MEM

  continually will memorize the present radio frequency in different channel

  The channel of max is 

10

Name of channel is 0-9

 

Ⅵ、

The volume can be changed by pressing key 

SET

VOL+

and

OPEN

 

11

Operation of Pump

 

The  Button 

,  operates  pump  1

The  Button   

PUMP2

operates    pump  2

The  button 

PUMP3

operates  pump  3

When  Circulation  cleaning  and  heating  (including  preheating)  turn  on,  circulation 

pump will be working automatically. 

 

12

Operation of lasting circulation cleaning

 

Press the key 

  at any time to turn on or off the lasting circulation cleaning, work mode is like the 

preset circulation cleaning.    The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer 

works for 15 minutes at every 105 minutes, and repeat in this program. 

  Once any surfing pumps or blower pump be start, the ozonizer without working.    The ozonizer can not 

work if the circulation pump is without working.

   

 

IMPORTANT

: Please ensure that the ozone function is not in use whilst bathing in the spa. 

 

13

Operation of spa lights

 

Press the

 

  button to 

control the ON/OFF of the LED lights and the Fiber optic lights. 

 
14

Setting the constant Temperature Settings

 

Summary of Contents for SPA-513

Page 1: ...1 HOT TUB Model SPA 513 OPERATING INSTRUCTION ...

Page 2: ...Surfing pump 1 On off SET Radio channel read Close view pump 2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with blue letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set pre heating set and display temperature 2 ...

Page 3: ...oller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and circulation cleaning function is off 2 Lock memory Mode optional function The memory lock will start work by pressing MEM key in the status of power off when the spa has not been adjusted for a period of 30 minutes When the memory locked key is pressed TWICE M...

Page 4: ...g the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and then the circulation works on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1 minute when pressing MIN each time and the minutes could be added continually The adjustment ...

Page 5: ... this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre h...

Page 6: ... heat On 图 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Continual time of preheating 4 Preset temperature 5 Finished ...

Page 7: ...will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 45 5 When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is...

Page 8: ...30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turned off automatically once the preset time is finished or Pressing the key can stop directly 8 Operation to Power ON OFF Pressing the key from power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen...

Page 9: ...emorize the present radio frequency in different channel The channel of max is 10 Name of channel is 0 9 Ⅵ The volume can be changed by pressing key SET VOL and OPEN 11 Operation of Pump The Button operates pump 1 The Button PUMP2 operates pump 2 The button PUMP3 operates pump 3 When Circulation cleaning and heating including preheating turn on circulation pump will be working automatically 12 Ope...

Page 10: ...can not start up However the corresponding signals will flash on the LCD 18 Prevent freezing function The heater circulation pump will work automatically once the water temperature is below 5 when the water temperature is reach at 10 heating will stop This function is only available while the spa is on normal power supply IV Electric parameters 1 Performance index Rated voltage 220V 50Hz Maximum w...

Page 11: ...perating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage system has to be provided to deal with overflow water Details of how to follow the wiring rules for example specifying that parts are installed in the correct zone and that equipotential bonding is carried out WARNING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protec...

Page 12: ...ange a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water...