6. Common problems and solutions

Although the products made from our factory have bean rigorous tested before send

out, but because of the transport environment is not expected , the error installation

and commissioning, the passage of time, individual electronic components aging

factors,will cause some problems. If your LED par light have some problems that

affect your normal use please refer to the following solutions or contact the dealer

directly.

LED par light problem and solution table

Problems

Reasons

Solutions

1.The light don’t light up, no
menu display, the fan can’t
running

1. Don’t have power
2.The power input circuit didn’t
connected

Connecting

the

power

correctly

2.One of the LED par didn’t
controlled by the signal

1.The address is incorrect, not in
the DMX mode
2.The Id code is incorrect, the
signal connecting is incorrect

Reset the parameter and
reconnecting

the

signal

cable

3.One of the LED par light is
running inconsistent to the
others

1.The LED par channel mode is
not the same

Readjust

4.One color of one LED par
light didn’t light up

The LED bead is virtual welding
or burned out

Well welding or replaced
the LED bead

Summary of Contents for PY5403

Page 1: ...Guangzhou Yingfeng Lighting Equipment Co Ltd www yf light com PY5403 LED PAR User Manual ...

Page 2: ... 3 Product parameter 02 A The fittings 02 B Product features 02 4 Channel mode 03 5 Operation introduction 05 1 Address setting 05 2 KEY dimming 05 3 Running sound control mode 05 4 Invoking the built in program 06 5 Channel mode selecting 06 6 Id address setting 06 6 Common problems and solutions 07 7 Points for attention 08 ...

Page 3: ...mental protection and with stable performance is welcomed by home and abroad customers 3 Product parameters A The fittings LED R12 G15 B15 W12 Voltage AC100 240V Frequency 50 60HZ Rated Power 160W Size 22 29 5 31 5cm Net weight 3 2kg DMX channels 5 6 8 11 channel B Product features 1 The scientific combination of LED matching the advanced optical lens make the excellent color mixing effects 2 AC10...

Page 4: ... bright 3 G green light 001 255 from dark to bright 4 B blue light 001 255 from dark to bright 5 W white light 001 255 from dark to bright 6 Automatic color 7 Strobe 001 255 from slow to fast 8 Macro 001 010 invalid 011 180 color change gradient 181 195 color jump 196 225 color pulse 226 255 sound control 9 Color gradient jump Pulse 001 255 from slow to fast 10 Dimming delay 11 Id extract 001 009 ...

Page 5: ...ight 001 255 from dark to bright 6 Strobe 001 255 from slow to fast 7 Macro 001 010 Invalid 011 180 color change gradient 181 195 color jump 196 225 color pulse 226 255 sound control 8 Macro speed Aod3 6CH 1 Master dimming 001 255 from dark to bright 2 R red light 001 255 from dark to bright 3 G green light 001 255 from dark to bright 4 B blue light 001 255 from dark to bright 5 W white light 001 ...

Page 6: ...mming Press the MENU key make the display return to A001 press DOWN key will display A then press ENTER will display CH01 CH01 indicated the 01 DMX channel of this LED par light then press UP or DOWN to select the other channel such as CH02 After select the channel press ENTER will display H000 H000 indicated the current selected channel value is 0 then press UP or Down key to change the channel a...

Page 7: ...ess ENTER to confirm 5 Channel mode selecting Press MENU make the display return to A001 press DOWN to find dΠP then press ENTER display od1 od1 indicated the first channel mode press UP or DOWN key can select the channel mode of 1 2 3 4 and so on at last press ENTER to confirm 6 Id address setting This LED par light can subdivided the same DMX address into 26 ID so save much channel for the conso...

Page 8: ... directly LED par light problem and solution table Problems Reasons Solutions 1 The light don t light up no menu display the fan can t running 1 Don t have power 2 The power input circuit didn t connected Connecting the power correctly 2 One of the LED par didn t controlled by the signal 1 The address is incorrect not in the DMX mode 2 The Id code is incorrect the signal connecting is incorrect Re...

Page 9: ...ut by professionals Don t use the dilute solvent such as alcohol to clean the surface of the lights The lights should not use in the ambient temperature which more than 40 degrees keep away from the fire and flammable things the lights should keep dry Hanging installation must be equipped with hook and safety rope which can carry the 10 times weight of the LED par light itself ...

Page 10: ...Guangzhou Yingfeng Lighting Equipment Co Ltd www yf light com ...

Reviews: