Compatibility:
When making PFAS connections, eliminate all possibility of roll-out. Roll-out
occurs when interference between a hook and the attachment point causes the hook gate to
unintentionally open and release. All connections must be selected and deemed compatible
with The Rack by a Competent Person. All connector gates must be self-closing and self-locking,
and withstand minimum loads of 3,600 lbs. See the following for examples of
compatible/incompatible connections:
Connector
closed and
locked to
D-ring.
OK.
Two or more
snap hooks or
carabiners
connected to
each other.
NO.
Two connectors
to same
D-ring.
NO.
Connector
directly to
horizontal
lifeline.
NO.
Connector
to integral
lanyard.
NO.
Connector
directly to
webbing.
NO.
Application
that places
load on gate.
NO.
Incompatible
or irregular
application,
which may
increase risk
of roll-out.
NO.