11
Sensitivity Auto-Learning
Following limit setting, the unit is now ready to learn the sensitivity for door
travel automatically. Proceed with the following steps to complete installa-
tion.
1. Both “UP” and “DOWN” LEDs are on after limit-setting, press the “FORCE”
button once to enter Sensitivity Auto-Learning mode.
2. The door will open and stop at UP limit for 2 seconds.
3. Door will then close and stop at down limit. The operator will beep 3 times; sensitivity
is learnt automatically, acknowledging that the sensitivity has been set.
X3
UP
RADIO SET FORCE
Summary of Contents for DCR2