19
!
WARNING
To prevent SERIOUS INJURY or DEATH from improper Force Adjustment:
- DO NOT adjust force to compensate binding or sticking of the garage door. Call a qualified garage door
service person to make necessary adjustments in case of binding.
- DO NOT increase force beyond minimum force required for closing the door. Too much force will cause
improper operation of safety reversal mechanism.
- After ANY adjustments, Safety Reverse Test MUST be performed to ensure the door reverses on contact
with a 1.5” high object (2x4 laid flat).
Travel Force Auto–Adjustment
Following limit-setting, the unit is now ready to
automatically adjust the forces for opening and closing the
door. Proceed with the following steps to complete
adjustment.
1.
With both “UP” and “DOWN” indicators are on after Travel
Limit Adjustment, press the “FORCE” button once to enter
Force Auto-Adjustment.
2.
The door will travel up automatically (
I
) and stop at UP
limit for 2 seconds (
II
). Door will then travel down
automatically (
III
) and stop at down limit (
IV
).
3.
The “OK” indicator (orange) will flash with beeps, the
Force Auto-Adjustment is completed.
2s
Stops at DOWN limit
Travels up
Stops at UP limit for
2 seconds
Travels down
I
II
III
IV
x2
Flashes
OK
x1
UP
DOWN
FORCE
LIMIT
UP
DOWN
1
2
3
Travel Force Auto-Adjustment