E-7
E-6
MAINTENANCE
·
Always unplug the unit before servicing it in any way.
·
The water temperature of the water remaining in the unit after use may be high.
·
Do not submerse the unit in water, or allow water to enter the inside of the unit.
INSIDE THE BODY OF THE UNIT
Pour excess water out of the unit, but do not allow it to enter the spout guide.
Wash out the unit with fresh water, using ONLY the cleaning brush and a soft
cloth as needed.
OUTER SURFACE OF THE UNIT
Wipe the surface of the unit with a soft damp cloth if needed.
WATER TANK
If water spots remain in the water tank, wipe the inside down with a soft cloth.
Do not use soap or detergents.
AIR FILTER
Gently wipe away debris from the filter with a soft cloth.
ULTRASONIC DISK
Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly remove build up
and deposits from this area (Fig. 2). White vinegar will help to prevent this build up.
STORAGE
·
Fully dry the inside and outside of the unit before storing it.
·
DO NOT leave water in the unit.
·
Store in a cool dry place.
TROUBLESHOOTING GUIDE
PROBLEM
SOLUTION
Water mist & humidity are not
produced.
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
Tank Installation: Make sure the tank is
correctly attached.
Air blows but water vapor is
not produced.
Excessive Water: Remove a certain amount of water from
the tank.
The desired humidity is lower than the current
temperature: Increase the desired humidity.
Detergent residue in tank: Wash the tank out
and try again.
Humidity level is low.
The surface of the ultrasonic disk is dirty: Wipe it off
with a soft, dry cloth. Clean with white vinegar.
The water in the unit is too cold: Replace with cool,
but not cold water.
Damage on the ultrasonicdisk: Exchange the disk.
Warm humidity is not produced.
The humidity has a bad smell.
Fig. 1
Fig. 2
White dust is forming on nearby
furniture.
Hard water may deposit a certain amount of dust. Dust in
the air also settles because of added humidity in the room.
Use distilled water if this becomes a nuisance.
**Clean the disk with
the brush ONLY. No
other cleaning tool
should be used.
BRUSH ONLY. (Fig. 2)
It may take 10-15 min. before warm humidity is created.
Check to see if base of unit feels warm to the touch.
If so warm mist is being produced.
Poor maintenance or dirty water: Clean the product
thoroughly, and fill it with fresh water.
Or order a
Decalcification Filter (FLTDC)
by calling 1.866.603.5900 or
visiting www.guardiantechnologies.com.