CONTROL PANEL FUNCTIONS

UV RESET

12H

6H

4H

OFF

UV-C ON/OFF Indicator 

Refill Indicator 

Heat ON/OFF Indicator 

Timer Indicator 

UV-C/Warm Mist Control 

Night Light

Timer Button

Mist Control and ON/OFF

1. Night Light

 

Press the Night Light button to turn

  night light on/off.

2. Timer

 

Press the Timer button to select either

  4, 6 or 12 hours. The unit will turn off in 

  that time.

3. Mist Control

 

Turn the power/mist control dial to 

  select mist level.

4. UV-C and Warm Mist Control

 

UV-C and Warm Mist ON/OFF Button Function:

  1st Press: UV-C ON

  2nd Press: UV-C & Warm Mist ON

  3rd Press: Warm Mist ON

  4th Press: Both OFF

5. Water Refill Indicator

 

When the unit is low on water the Refill

LED on the front panel will light up, and

  the unit will shut off. Simply add more

  water to continue use. Unit will

  automatically resume running when

  water tank has been refilled.

6. UV-C Light Replacement Indicator

 

When the UV-C light needs replacing the

  UV-C Replacement LED will light up.

  See instructions on page E8 for replacing

  the UV-C light and resetting the indicator.

7. Humidity Spout Dual Direction

 

Broaden mist in two different directions

  throughout the room by rotating top section.

1. Always unplug the unit before servicing in any way.

2. The water temperature of the water in the unit after use may be high, allow time for it to cool.

GENERAL CLEANING

3. Inside the base of the unit. 

Pour excess water out of the unit. Wash out the unit with fresh water

  using the cleaning brush and a soft cloth as needed. 

Do not submerse the base of the unit into 

  water, or allow water to enter inside the dry air exhaust port of the unit.

4. Water tank. 

Empty water tank. Remove mist nozzle and clean the mist tube with fresh water. 

5. Outer surface of the unit. 

Wipe the lid and surface of the unit with a soft, damp cloth if needed. 

  If you notice an accumulation of water during usage, reduce humidity and dry outer surface with a cloth.

DESCALING

• Depending on usage and water type, cleaning to remove scale may be required

  weekly or every other week to optimize unit performance.

• If you live in a hard water area, we recommend the use of distilled water for your

  humidifier. This will help reduce the precipitation of minerals or ‘white dust’.

• Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.

ULTRASONIC DISK

1. 

Unplug unit.

2. 

Remove the tank and empty all water from unit base and tank.

3. 

Locate the ultrasonic disk on the inside center of the base unit.

4. 

Use ONLY the enclosed cleaning brush to gently clean disk and 

  remove build up and deposits. 

  Do not scrub or scrape the ultrasonic disk.
Are minerals in your water producing white dust?

Try Decalcification Cartridge 

FLTDC.

Look for cartridge           at your local retailer or visit 

www.guardiantechnologies.com

CLEANING

If scale becomes difficult to remove with brush:

1. 

Fill the Base with: mixture of 1 tsp. white vinegar and 1 tsp. water.

2. 

Let solution stand for 5 minutes.

3. 

With the vinegar in the tank, clean all interior surfaces with a soft cloth or brush to help remove scale.

4. 

Also check mist nozzle and mist tube in water tank. Clean as needed.

5. 

Rinse the tank thoroughly with water to remove scale and vinegar solution.

END OF SEASON STORAGE

Follow the Cleaning and Descaling instructions when the humidifier will be stored at 

  the end of the season.

Dry the humidifier completely before storing. DO NOT store with water inside the 

  Base or Water Tank.

Pack the unit in its original carton and store in a cool, dry location.

NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING 

YOURSELF. DOING SO MAY VOID YOUR WARRANTYAND CAUSE DAMAGE TO THE HUMIDIFIER 

OR PERSONAL INJURY.

1

Ultrasonic Disk

(Looking down

into base of unit)

Summary of Contents for H5450

Page 1: ...tilize this warranty according to the conditions stated above To submit product under warranty the complete machine must be delivered pre paid to Guardian Technologies LLC Please include complete info...

Page 2: ...one is home Do not keep water in the tank when not in use for an extended period of time Do not clean the unit water tank or water reservoir with detergents or chemicals of any kind The use of water...

Page 3: ...it to the right It is important to FIRMLY secure cap after filling the tank with water 5 Attach the tank to the base of the unit and plug in 6 POWER BUTTON Before turning on make sure there is water i...

Page 4: ...rface of the unit with a soft damp cloth if needed If you notice an accumulation of water during usage reduce humidity and dry outer surface with a cloth DESCALING Depending on usage and water type cl...

Page 5: ...has not been set Water is accumulating outside of unit or area surrounding unit Saturation of humidity Lower mist control setting Unit not level and water is accumulating Unplug and place on level sur...

Page 6: ...autre aux tats Unis L enregistrement de garantie de l appareil peut se faire en ligne l adresse www guardiantechnologies com Nous consid rons le processus d enregistrement comme important afin d assu...

Page 7: ...prolong e ou lorsque personne n est la maison Ne laissez pas d eau dans le r servoir lorsque vous n utilisez pas l appareil pendant une p riode prolong e Ne nettoyez jamais l appareil ni le r servoir...

Page 8: ...ournant vers la droite Il est important de BIEN serrer le bouchon apr s avoir rempli le r servoir d eau 5 Rattachez le r servoir la base de l appareil et branchez le 6 BOUTON MARCHE ARR T Avant de met...

Page 9: ...rieur de l appareil Essuyez la surface de l appareil l aide d un chiffon doux et humide au besoin Si vous remarquezune accumulation d eau pendant le fonctionnement de l appareil r duisez l humidit et...

Page 10: ...i aucune humidit ne sont mises Prise d alimentation d branchez l appareil et rebranchez le pour r essayer Panne de courant r essayez une fois la panne termin e Installation du r servoir v rifiez que l...

Page 11: ...do en los EE UU Puede completar el registro de la garant a en l nea en www guardiantechnologies com Consideramos que el proceso de registro es importante para garantizar el servicio superior a nuestro...

Page 12: ...aso de que la unidad haya sido colocada de manera incorrecta No lo utilice si el enchufe est da ado o suelto Antes de llenar o limpiar la unidad aseg rese de que est desconectada Una vez que haya cone...

Page 13: ...la tapa despu s de llenar el dep sito con agua 5 Vuelva a colocar el dep sito en la base de la unidad y con ctela 6 BOT N INTERRUPTOR Antes de encender la unidad verifique que la unidad est llena de a...

Page 14: ...illo suave se recomienda usar un cepillo para limpiar botellas Superficie externa de la unidad De ser necesario limpie la superficie externa de la unidad con un pa o suave h medo Si observa acumulaci...

Page 15: ...ad est apareciendo un polvo blanco El agua dura puede crear ciertos dep sitos de polvo El polvo en el aire tambi n se asienta debido a la humedad de la habitaci n Si le molesta este polvo use agua des...

Reviews: