background image

Deutsch / 

Français

Technical Specifications

Conforming to standard

EN 292, EN 1088,
IEC 947-5-1, GS-ET -19

Contacts
   all types except RPS11

4 N/O

   type RPS11

2 N/O + 2 N/C

Rating

IP20

Finger protection

DIN 57106/VDE 0106 T.100

Ambient temp.

-10

°

C to +40

°

C

Mechanical operations

1 x 10

5

Max. shear force to key

15.1kN

Max. torque to key

14Nm

Relative operating humidity

25% to 95%

Weight

0.85kg

Code barrels

Tested to 1,000,000 operations

Isolator approved

SA, S, S

+

, UL, D, Fl

Electrical operations

>10

5

Climatic test

Constant to DIN IEC 68 Part 2-3
Variable to DIN IEC 68 Part 2-30

Ambient temp.

Encased -25

°

C to +40

°

C

Rtd. insulation voltage (U

i

)

690V

Rtd. impulse withstand vol. (U

imp

)

6kV

S3 intermittent rating (VDE 0530
Part 1) duty factor

60/40/25%=1,3/1,6/2xl

u

Rtd. uninterrupted current (I

u

)

IEC/EN/VDE

20A

32A

63A

100A

UL/CSA

16A

30A

60A

100A

Rtd. operational voltage (U

e

)

IEC/EN/VDE

690V

690V

690V

1000A

UL/CSA

600V

600V

600V

600V

Main switch isol. voltage up to

750V

750V

750V

1000V

Rtd. operational current (I

e

)

AC-21A IEC/EN/VDE

20A

32A

63A

100A

AC-1 SEV

20A

32A

63A

100A

Rtd. operational power at 50 to 60Hz
AC-23A IEC/EN/VDE
3 phase    220-240V

4kW

7.5kW 15kW

22kW

3 pole       380-440V

7.5kW 15kW

30kW

37kW

                 500-690V

7.5kW 11kW

30kW

37kW

AC-3 IEC/EN/VDE
3 phase    220-240V

3kW

5.5kW 11kW

22kW

3 pole       380-440V

5.5kW 11kW

22kW

37kW

                 500-690V

5.5kW 11kW

22kW

30kW

DOL-rating UL/CSA
3 phase    120V

1.5HP 3HP

5HP

7.5HP

3 pole       240V

3HP

10HP

15HP

30HP

                480V

7.5HP 20HP

30HP

50HP

                600V

10HP

20HP

40HP

50HP

Rated breaking capacity
AC-23/AC-3  220-240V

250A

330A

500A

600A

Motor switch  380-440V

250A

330A

500A

600A

                     500-690V

150A

220A

270A

300A

Max. fuse size (gL)

25A

35A

63/50A 100A

Rated fuse short circuit current

15kA

15kA

15/25kA 25kA

Terminal cross section
Single/multiple wire    min. mm

2

1

1

4

2.5

                                    max. mm

2

10

10

16

3.5

Fine strand wire           min. mm

2

0.75

0.75

2.5

1.5

with sleeve                   max. mm

2

6

6

10

25

American wire guage

8

8

6

2

Spécifications techniques

Technische Daten

(r)

(d)

(a) 

DIMENSIONS / ABMESSUNGEN / DIMENSIONS

(b)

SCHUTZKLAPPE

 / 

CHAPEAU DE 

PROTECTION

(c)

CODE-ZYLINDER

 / 

BARILLET A CODE

(d)

MAX. WANDSTÄRKE 5 mm

 / 

EPAISSEUR 

MAXIMALE DU PANNEAU: 5 mm

(e)

NOMENKLATURSCHILD

 / 

PLAQUE DE 

LEGENDE

(f)

MONTAGESCHRAUBEN

 / 

VIS DE 

FIXATION

(g)

SCHALTEREINHEIT

 / 

INTERRUPTEUR

64

64

64

SWITCH UNIT

CODE BARREL

5mm MAX PANEL THICKNESS

WEATHER CAP ASSY

LEGEND PLATE

FIXING SCREWS

(b)

(c)

(e)

(f)

(g)

OFF

ON

68

Konformität mit folgenden Normen

EN 292, EN 1088,

IEC 947-5-1, GS-ET -19

Kontakte
alle Typen außer RPS11

4 Schließer

Typ RPS11 

2 Schließer + 2 Öffner

Schutzklasse 

IP20

Fingerschutz 

DIN 57106 / VDE 0106 T.100

Umgebungstemperatur

-10 

°

 bis +40 

°

C

Mechanische Lebensdauer 

1 x 10

5

 Schaltspiele

Max. Schlüssel-Scherkraft 

15,1 kN

Max. Schlüssel-Drehmoment 

14 Nm

Relative Luftfeuchtigkeit für Betrieb  25% bis 95%
Gewicht 

0,85 kg

Code-Zylinder 

auf 1.000.000 Schaltspiele getestet

Isolator-Zulassung durch 

SA, S, S

+

,  UL, D, Fl

Elektrische Schaltspiele 

> 10

5

Klimatest 

Konstant nach DIN IEC 68, Teil 2-3
Variabel nach DIN IEC 68, Teil 2-30

Umgebungstemperatur  

(eingebaut) -25 

°

 bis + 40 

°

C

Bemessungs-Isolationsspannung 

(U

i

)

  690 V

Bemessungs-Stoßspannung (

U

imp

)  6 kV

S3-Aussetzleistung (VDE 0530, Teil 1), 
relative Einschaltdauer 

60 / 40 / 25% = 1,3 / 1,6 / 2xlu

Bemessungs-Dauerstrom 

(I

u

)

IEC / EN / VDE

20 A    32 A    63 A    100 A

UL / CSA 

16 A    30 A    60 A    100 A   

Bemessungs-Betriebsspannung 

(U

e

)

IEC / EN / VDE

690 V    690 V    690 V    1000 A

UL / CSA 

600 V    600 V    600 V     600 V

Max. Hauptschalter-Isolationsspannung  750 V    750 V    750 V    1000 V
Bemessungs-Betriebsstrom 

(I

e

)

AC-21 A IEC / EN / VDE

20 A    32 A    63 A    100 A

AC-1 SEV 

20 A    32 A    63 A    100 A

Bemessungs-Betriebsstrom bei 
50 bis 60 Hz
AC-23 A IEC / EN / VDE
3-phasig  220-240 V

4 kW      7,5 kW    15 kW   22 kW

3-polig     380-440 V

7,5 kW  15 kW    30 kW   37 kW

               500-690 V 

7,5 kW 11 kW    30 kW   37 kW

AC-3 IEC / EN / VDE
3-phasig  220-240 V

3 kW      5,5 kW    11 kW   22 kW

3-polig     380-440 V

5,5 kW 11 kW    22 kW   37 kW

                500-690 V 

5,5 kW 11 kW    22 kW   30 kW

Direktstart-Bemessungswerte nach 
UL / CSA
3-phasig   120 V

1,5 PS 3 PS      5 PS    7,5 PS

3-polig      240 V

3 PS     10 PS    15 PS    30 PS

                 480 V

7,5 PS    20 PS    30 PS    50 PS

                 600 V 

10 PS

20 PS    40 PS    50 PS 

Bemessungs-Ausschaltleistung
AC-23/AC-3     220-240 V

250 A    330 A    500 A    600 A

Motorschalter   380-440 V

250 A    330 A    500 A    600 A

                        500-690 V 

150 A    220 A    270 A    300 A

Max. Sicherungsgröße (gL) 

25 A    35 A   

63/50 A 100 A

Bem. Sicherungs-Kurzschlußstrom   15 kA    15 kA    15/25 kA  25 kA
Klemmenquerschnitt
Einzel-/Mehrfachkabel min.  mm

2

1            1         4         2,5

                                   max. mm

2

  10        10       16         3,5 

Feinadriges Kabel        min.  mm

2

0,75    0,75    2,5     1,5

mit Muffe                    max.  mm

2

  6          6       

10      25

Amerikanisches Drahtmaß

8          8         6        2

Conforme aux normes suivantes 

EN 292, EN 1088,

IEC 947-5-1, GS-ET -19

Contacts
Tous les types hormis RPS11

4 N/O

RPS11 

2 N/O + 2 N/F

Protection 

IP20

Protection des doigts 

DIN 57106/VDE 0106T.100

Temp. ambiante 

-10

°

C à +40

°

C

Opérations mécaniques 

1 x 10

5

Force de cisaillement maxi sur la clé 15.1 kN
Couple maxi sur la clé

14 Nm

Humidité relative en service 

25% à 95% 

Poids 

0,85 kg

Barillets codés 

Testés jusqu’à 1 000 000 opérations

Homologation de l’isolateur 

SA, S, S

+

, UL, D, Fl

Actionnements électriques 

>10

5

Essais climatiques 

Constant conf. DIN IEC 68 part. 2-3
Variable conf. DIN IEC 68 part. 2-30

Temp. ambiante 

-10

°

C à +40

°

C en boîtier 

Tension nominale d’isolation 

(U

i

)

  690 V

Tension nominale de résist. aux imp. (

U

imp

)  6 kV

Régime intermittent S3 (VDE 0530 
Part. 1) facteur de service 

60/40/25% = 1,3/1,6/2xlu

Courant ininterrompu nominal 

(I

u

)

IEC/EN/VDE

20A

32A

63A

100A

UL/CSA 

16A 

30A

60A

100A

Courant nominal de service (U

e

)

IEC/EN/VDE

690V 690V

690V

1000A

UL/CSA 

600V 600V

600V

600V

Tension d’isol. de l’interrupt. principal, jusqu’à 750V  750V  750V 

1000V

Courant nominal de service (I

e

)

AC-21A IEC/EN/VDE

20A

32A

63A

100A

AC-1 SEV 

20A

32A

63A

100A

Puissance nominale de service, 
50 à 60Hz
AC-23A IEC/EN/VDE
Triphasé    220 - 240 V

4kW

7,5kW 15kW

22kW

Tripolaire  380- 440 V

7,5kW 15 kW 30kW

37kW

                500 - 690 V 

7,5kW 11kW 30kW

37kW

AC-3 IEC / EN / VDE
Triphasé    220-240V

3kW

5,5kW 11kW

22kW

Tripolaire  380-440V

5,5kW 11 kW 22kW

37kW

                500-690V

5,5kW 11kW 22kW

30kW

Dir. en ligne -UL/CSA
Triphasé    120 V

1,5HP 3HP

5HP

7,5HP

Tripolaire   240 V

3HP

10HP 15HP

30HP

                 480 V

7,5HP 20HP 30HP

50HP

                 600 V 

10HP 20HP 40HP

50HP 

Puissance nominale de rupture
AC-23/AC-3              220-240 V

250 A 330 A 500 A

600 A

Interrupt. du moteur 380 - 440 V 250 A 330 A 500 A

600 A

                               500 - 690 V  150 A 220 A 270 A

300 A

Puiss. nom. du fusible (gL) 

25A 

35A 

63/50 A  100 A

Courant nominal de court-circuit   15 kA  15 kA  15/25 kA  25 kA
du fusible
Section transv. des bornes
Fil unique/multiple   mini./mm

2

1

1

4

2,5

                                maxi./mm

2

  10 

10

 16 

3,5

Fil torsadé fin      mini./mm

2

0,75

0,75

2,5

1,5

avec gaine           maxi./mm

2

 

6

6

10

25

Calibre américain de fil (AWG) 

8

 8 

2

Summary of Contents for PROSAFE RPSE Series

Page 1: ... vérifier que les caractéristiques de cet appareil sont appropriées aux critères d utilisation et d environnement de la machine Pendant toute la vie de la machine en respectant des périodes de vérification régulières assurez vous que l appareil conserve ses performances inspectez le montage du dispositif pour déceler des traces éventuelles d usure de dégradation ou de fraudes Si nécessaire remplac...

Page 2: ...ssemblage est correct bloquer avec un vernis ou un composant similaire 3 b Alle Typen außer RPS 11 abgebildet 4 Schließer mit Schlüssel frei abziehbar Tous les types RPS11 exclu 4 N O représenté avec clé libre c Typ RPS 11 abgebildet 2 Schließer 2 Öffner mit Schlüssel frei abziehbar Type RPS11 2 N O 2 N F représentés avec clé libre 4 b c d b Korrekte Funktion prüfen Sicherstellen daß der Strom get...

Page 3: ...sungs Dauerstrom Iu IEC EN VDE 20 A 32 A 63 A 100 A UL CSA 16 A 30 A 60 A 100 A Bemessungs Betriebsspannung Ue IEC EN VDE 690 V 690 V 690 V 1000 A UL CSA 600 V 600 V 600 V 600 V Max Hauptschalter Isolationsspannung 750 V 750 V 750 V 1000 V Bemessungs Betriebsstrom Ie AC 21 A IEC EN VDE 20 A 32 A 63 A 100 A AC 1 SEV 20 A 32 A 63 A 100 A Bemessungs Betriebsstrom bei 50 bis 60 Hz AC 23 A IEC EN VDE 3...

Page 4: ...und ggf austauschen Das Schloß wieder einbauen und die Schrauben sichern Strom erneut einschalten und die korrekte Funktion des Schalters prüfen Die Schrauben mit einer Kennzeichnung aus Farblack oder einem ähnlichen Material erneut versiegeln Toutes les semaines Vérifiez que le circuit d interruption fonctionne correctement et inspectez pour déceler des signes éventuels de manipulations non autor...