77
Expert Power Control 8001
© 2022 GUDE Systems GmbH
Specifications
radius {PRIMARY=0|SECONDARY=1} server set
"<dns_name>"
sets radius server address
radius {PRIMARY=0|SECONDARY=1} server
show
show s radius server address
radius {PRIMARY=0|SECONDARY=1} passw ord
set "{passw d}"
sets radius server shared secret
radius {PRIMARY=0|SECONDARY=1} passw ord
hash set "{passw d}"
sets radius server crypted shared secret
radius {PRIMARY=0|SECONDARY=1} auth timeout
set {num_secs}
sets server request timeout
radius {PRIMARY=0|SECONDARY=1} auth timeout
show
show s server request timeout
radius {PRIMARY=0|SECONDARY=1} retries set
{0..99}
sets server number of retries
radius {PRIMARY=0|SECONDARY=1} retries
show
show s server number of retries
radius chap enabled set <off=0/on=1>
enables CHAP
radius chap enabled show
show s if CHAP is enabled
radius message auth set <off=0/on=1>
enables request message authentication
radius message auth show
show s if request message authentication is
enabled
radius default timeout set {num_secs}
sets default session timeout (w hen not returned
as Session-Timout Attribute)
radius default timeout show
show s default session timeout
snmp
enters cmd group "snmp"
snmp port set {ip_port}
sets SNMP UDP port
snmp port show
show s SNMP UDP port
snmp snmpget enabled set {OFF=0|ON=1}
enables SNMP GET cmds on/off
snmp snmpget enabled show
show if SNMP GET cmds are enabled
snmp snmpset enabled set {OFF=0|ON=1}
enables SNMP SET cmds on/off
snmp snmpset enabled show
show if SNMP SET cmds are enabled
snmp snmpv2 enabled set {OFF=0|ON=1}
enables SNMP v2 on/off
snmp snmpv2 enabled show
show if SNMP v2 is enabled
snmp snmpv2 public set "{text}"
enables SNMP v3 on/off
snmp snmpv2 public show
show if SNMP v3 isenabled
snmp snmpv2 private set "{text}"
sets SNMP v2 public cummnity
snmp snmpv2 private show
show s SNMP v2 public community
snmp system {CONTACT=0|NAME=1|
LOCATION=2} set "{text}"
sets sysLocation/sysName/sysContact
snmp system {CONTACT=0|NAME=1|
LOCATION=2} show
gets sysLocation/sysName/sysContact
snmp snmpv3 enabled set {OFF=0|ON=1}
sets SNMP v2 private community
snmp snmpv3 enabled show
show s SNMP v2 private community
snmp snmpv3 username set "{text}"
sets SNMP v3 username
snmp snmpv3 username show
show s SNMP v3 username
snmp snmpv3 authalg set {NONE=0|MD5=1|
SHA1=2|SHA256=3|SHA384=4|SHA512=5}
sets SNMP v3 authentication
snmp snmpv3 authalg show
show SNMP v3 authentication algorithm
snmp snmpv3 privalg set {NONE=0|DES=1|
3DES=2|AES128=3|AES192=4|AES256=5|
AES192*=6|AES256*=7}
sets SNMP v3 privacy algorithm
snmp snmpv3 privalg show
show SNMP v3 privacy algorithm
snmp snmpv3 authpassw d set "{passw d}"
sets SNMP v3 authentication passw ord
snmp snmpv3 privpassw d set "{passw d}"
sets SNMP v3 privacy passw ord
snmp snmpv3 authpassw d hash set "{passw d}" sets SNMP v3 authentication hashed passw ord
snmp snmpv3 privpassw d hash set "{passw d}" sets SNMP v3 privacy hashed passw ord
snmp trap type set {NONE=0|V1=1|V2=2|V3=3}
sets type of SNMP traps
snmp trap type show
show SNMP trap type
snmp trap receiver {trap_num} set "{dns_name}"
sets address and port of SNMP trap receiver
{trap_num}
snmp trap receiver {trap_num} show
show address and port of SNMP trap receiver
{trap_num}
syslog
enters cmd group "syslog"