79
Expert Power Control 8221/8226
© 2022 GUDE Systems GmbH
Specifications
linesensor {line_num} {energy_sensor} publish
timer show
show s publish time interval
linesensor {line_num} {energy_sensor} publish
delta set {float}
sets publish delta value
linesensor {line_num} {energy_sensor} publish
delta show
show s publish delta value
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
sets Port for Pow er Port Sw itching actions
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
show s Port for Pow er Port Sw itching actions
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
sets Port state for Pow er Port Sw itching actions
linesensor {line_num} {energy_sensor}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
show s Port state for Pow er Port Sw itching
actions
linesensor {line_num} events set {OFF=0|ON=1}
LEGACY - enables events on/off
L
linesensor {line_num} events show
LEGACY - show s if events are enabled
L
linesensor {line_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5,E
VT_DISPLAY=6,EVT_CONSOLE=7,EVT_MQTT=8}
"
LEGACY - enables different event types
L
linesensor {line_num} events type show
LEGACY - show s w hat event types are enabled
L
linesensor {line_num} maxval set {float}
LEGACY - sets maximum value for line meter
L
linesensor {line_num} maxval show
LEGACY - show s maximum value for line meter
L
linesensor {line_num} minval set {float}
LEGACY - sets minimum value for line meter
L
linesensor {line_num} minval show
LEGACY - show s minimum value for line meter
L
linesensor {line_num} hyst set {float}
LEGACY - sets hysterese value for line meter
L
linesensor {line_num} hyst show
LEGACY - show s hysterese value for line meter
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
set {port_num}
LEGACY - sets Port for Pow er Port Sw itching
actions
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
show
LEGACY - show s Port for Pow er Port Sw itching
actions
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state set {OFF=0|ON=1|DISABLED=2}
LEGACY - sets Port state for Pow er Port
Sw itching actions
L
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state show
LEGACY - show s Port state for Pow er Port
Sw itching actions
L
linesensor beeper set {OFF=0|ON=1}
enables beeper for line meter alarms
linesensor beeper show
show s if beeper for line meter alarms is enabled
modbus
enters cmd group "modbus"
modbus enabled set <off=0/on=1>
enables Modbus TCP support
modbus enabled show
show s if Modbus is enabled
modbus port set <ip_port>
sets Modbus TCP port
modbus port show
show s Modbus TCP port
mqtt
enters cmd group "mqtt"
mqtt {broker_idx} enabled set {OFF=0|ON=1}
enable mqtt
mqtt {broker_idx} enabled show
show s if mqtt enabled
mqtt {broker_idx} server set "{dns_name}"
sets broker name
mqtt {broker_idx} server show
show s broker name
mqtt {broker_idx} tls enabled set {OFF=0|ON=1}
enable TLS
mqtt {broker_idx} tls enabled show
show s if TLS enabled
mqtt {broker_idx} port set {ip_port}
set broker TCP/IP port
mqtt {broker_idx} port show
show s broker TCP/IP port
mqtt {broker_idx} user set "{username}"
sets username
mqtt {broker_idx} user show
show s username
Summary of Contents for Expert Power Control 8221 Series
Page 2: ...2 Expert Power Control 8221 8226 2022 GUDESystems GmbH ...
Page 5: ...Device Description ...
Page 14: ...Operating ...
Page 25: ...Configuration ...
Page 54: ...Specifications ...
Page 109: ...Support ...