12
AIRPOWER 180/08
ENGLISH
G
B
Warning/caution!
Dangerous voltage
Caution - hot surface!
Warning, hot surfaces!
Danger - automatic control (closed loop)
Warning against thrown-off items
Keep distance of persons!
Observe to keep out of dangerous zone
Any damaged or disposed electric or
electronic devices must be delivered to
appropriate collection centres.
Protect against humidity
This side up
EC-Declaration of Conformity
GÜDE GmbH & Co. KG
birkichstrasse 6, 74549 Wolpertshausen
Deutschland
We, hereby declare the conception and construction
of the below mentioned appliances correspond - at
the type of construction being launched - to appro-
priate basic safety and hygienic requirements of EC
Directives. In case of any change to the appliance not
discussed with us the Declaration expires.
Compressor AIRPOWER 180/08 #50077
Appropriate EU Directives
2006/42 EG, 2004/108 EG, 2000/14 EG
Harmonised standards used
EN 1012:2010
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 +
A2:2006 + A13:2008 + A14:2010
EN 60204-1:2011
EN 55014-1:2006 + A1:2009
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
Wolpertshausen, 2012-05-16
Helmut Arnold
Managing Director
Technical documentation
joachim bürkle
Failure removal
Defect
Causes
measure
Compressor not starting after
being switched on
Defective supply
Have the current supply checked by
an authorised person
Worn carbons
Replace the carbons
Compressor getting warm too
much
Air supply is not sufficient
Make sure sufficient air supply and
outlet (minimum distance from wall
is 40 cm) is provided
Too long time of appliance
operation
Switch the compressor off
Compressor being overheated
and keeps switching off
Compressor is overloaded
Contact the Güde service centre
Compressor is defective
Contact the Güde service centre
Compressor under undervoltage
Contact the Güde service centre
Outdoor temperature of 35°C
Güde 50077 Kompressor Airpower 180_08_1.0.indd 12