EU Declaration of Conformity
We,
Güde GmbH & Co. KG
Birkichstraße 6
74549 Wolpertshausen
Germany
hereby declare the conception and construction of the below-mentioned appliances correspond - at the type of construction being
launched - to appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us the Declaration expires.
Marking of appliances:
DHH 1050/10 TP WOOD SPLITTER
Order No.:
02003
Date/producer signature:
27.03.2012
Signed by:
Managing Director
Mr.
Arnold
Technische Dokumentation:
J. Bürkle FBL; QS
Appropriate EU Directives
:
2004/108/EG
2006/42/EG
Harmonised standards used:
EN 609-1/A2:2009
EN 61000-3-3:1995+A1+A2
EN 61000-3-2:2006
EN 55014-2:1997+A1
EN 55014-1:2006
Noise level:
Lwa: 85,2 dB
Lpa: 69,9 dB
Troubleshooting
Problems
Possible causes
Remedy
Engine not starting
1. No current in the outlet
2. Defective extension cable
3. Wrong feeder cable
4. Defective switch, condenser
1. Check the network protection
2. Pull out the plug – check it and replace it if necessary
3. Connection with 5 cores with a cross section of 2.5 mm
2
4. Have the appliance checked by an electrician
Wrong engine running
direction
1. Wrong connection
1. Turn the phase changer in the appliance plug using a
screwdriver
Splitting knife not moving
1. Two-hand switching lever adjustment 1.
Check the oil level
Defective control valve must be replaced in a service
centre only
Splitter has no power
1. Wrong
rotation
direction
2.
Too little hydraulic oil
3.
Starting rod is bent; the hydraulic
lifter is not pressed to the full extent
4.
Wood with too many knots - splitting
knife gets jammed
5.
Operating arm is bent
1. Change the rotation direction
2. Add hydraulic oil
3.
Check all screws on the starting rod mechanism
Adjust the pull rod (pic. 10/B); by this,
the hydraulic lifter will be pressed to the full extent.
4. Lubricate the splitting knife with fat.
5. Return the operating arm to the starting position.
After being pressed, the
green switching button not
staying in place
1. Defective fuse, etc.
2. 2 phase running
1. Check the cable
Hydraulic pump whistling;
splitting knife running jerky
1.
Oil loss, surface is dirty
2.
Too little hydraulic oil in the tank
1.
Tighten the screwing
Replace the hoses
2. Add hydraulic oil