7
Expert Net Control 2312
Device Description
Start-up the device
·
Connect the device to an AC Adaptor (12V-24V AC or DC).
·
Plug the network cable into the Ethernet socket (RJ45).
·
Connect the neutral wire to the neutral wire connector (11).
·
Connect the relay outputs to the loads that should be used.
·
Connect the relay inputs with the corresponding phase
·
Attach a switch (if any) to the stop input.
·
Connect the sensor (if any) to the device.
Stop Input
1.5
Stop Input
If the Stop Input is set to LOW for a second, all relays are switched off immediately. If a shutdown
was initiated, and the Stop Input goes back to HIGH for a second, the relay will re-activate as if the
device is started again. See Initialization Initialization status and Initialization delay in the chapter
"Configuration - Output Ports".