background image

16

Expert PDU energy 8310

Contact

Declarations of conformity

8

EG Konformitätserklärung

EC Declaration of Conformity

Der Hersteller
The manufacturer

Gude Analog- und Digitalsysteme GmbH

Eintrachtstr. 113

50668 Köln (Deutschland)

erklärt hiermit, dass die folgenden Produkte / hereby declares that the following products

Produktbezeichnung
Product name

Expert PDU energy 8310

Expert PDU energy 8310-1

Beschreibung

Description

Stromverteilung mit IP basierter Energiemessung

power distribution unit with IP based energy monitoring

mit den Bestimmungen der nachstehenden EU-Richtlinien übereinstimmen  / are in accor-
dance with the following European directives

2006/95/EG

2006/95/EC

Niederspannungsrichtlinie

Low Voltage Directive (LVD)

2004/108/EG

2004/108/EC

Elektromagnetische Verträglichkeit (EMV)

Electromagnetic Compatibility (EMC)

2011/65/EU

zur Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elek-

tro- und Elektronikgeräten (RoHS)

on the restriction of the use of certain hazardous substances in electrical and electronic

equipment (RoHS)

und dass die nachstehenden harmonisierten Europäischen Normen zur Anwendung gelangt
sind. / and comply with the following harmonised European standards.

EN 60950-1:2006 /
AC:2011

Einrichtungen der Informationstechnik - Sicherheit / Information technology equipment - Safe-

ty

EN 55022:2010

Einrichtungen der Informationstechnik - Funkstöreigenschaften / Information technology

equipment - Radio disturbance characteristics

EN 55024:2010

Einrichtungen der Informationstechnik - Störfestigkeitseigenschaften / Information technology

equipment - Immunity characteristics

EN 50581:2012

Technische Dokumentation zur Beurteilung von Elektro- und Elektronikgeräten hinsichtlich

der Beschränkung gefährlicher Stoffe / Technical documentation for the assessment of elec-

trical and electronic products with respect to the restriction of hazardous substances

Köln, 09.07.2013

Dr. Michael Gude, Geschäftsführer / General manager, CEO

Summary of Contents for Expert PDU Energy 8310 Series

Page 1: ...2014 Gude Analog und Digitalsysteme GmbH Manual Ver 1 1 0 valid from Firmware Ver 1 1 1 Expert PDU Energy 8310 Series...

Page 2: ...ith your smartphone the important operating figures of your server and rack environment like sensor values max min energy consumption as well as state of inputs and outputs with watchdog functions In...

Page 3: ...k settings with GBL_Conf 7 4 3 Configuration via webinterface 4 3 1 Configuration IP Address 7 4 3 2 Configuration IP ACL 8 4 3 3 Configuration HTTP 9 4 3 4 Configuration Sensors 10 4 3 5 Configuratio...

Page 4: ...re not clear after reading the ma nual please do not hesitate to ask our support team Description 2 The Expert PDU energy 8310 is a multiple socket outlet with CEE 7 4 sockets model 8310 or IEC C13 so...

Page 5: ...s informations and statistics are available on the display Each time you press the but ton a new page is shown on the LCD display 227V 0 0A 0W 0 000kWh This is the usual energy view On the top line is...

Page 6: ...via the web interface Network settings with GBL_Conf 4 2 For changing the network properties manually the program GBL_Conf exe is required This tool is available for free on our website www gude info...

Page 7: ...ttp IP address of unit and press LOGIN To enter the configuration menu click on Configuration Tab Configuration IP Address 4 3 1 Hostname 4 3 1 1 Enter the hostname of the device The hostname is used...

Page 8: ...Netmask and a standard Gateway from this server If there is no DHCP server inside of your network we recom mend to deactivate this function For the changes to get valid a restart of the firmware is r...

Page 9: ...he firmware is required Require HTTP Password 4 3 3 2 Password protected access can be activated here In this case a user and an admin password have to be defined Pass words have a maximum lengths of...

Page 10: ...s up to 24 hours Hysteresis 4 3 4 3 Here you can specify a threshold that is reached after crossing a threshold in order to signal that falls below the threshold example Limit 10 C Action Output alarm...

Page 11: ...P communites like read write passwords SNMP v1 and v2 transmit the communities without encryption There fore it is simple to spy out these communities We recommend to use a DMZ or IP ACL 4 3 5 1 2 MIB...

Page 12: ...wnload SNMP MIB 4 3 5 6 Here you can download the MIB Configuration Syslog 4 3 6 Syslog messages are simple text messages transmitted to a syslog server using UDP Linux OS regularly have a syslog daem...

Page 13: ...1 Here you can activate the e mail function of the device E Mail server 4 3 7 2 Enter the e mail server e g mail gmx net Sender address 4 3 7 3 Enter the address the device should use when sending e m...

Page 14: ...the device status LED is slow the blinking In bootloader mode you can disable the password and IP ACL it is possible to use the program GBL_Conf exe to perform a firmware update and factory settings...

Page 15: ...will be loaded when the firmware of the device is re started the next time Support 6 In case of further questions about installation or operation of the device please have look at www gude info wiki...

Page 16: ...estimmter gef hrlicher Stoffe in Elek tro und Elektronikger ten RoHS on the restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS und dass die nachstehende...

Page 17: ...Expert PDU energy 8310 2014 Gude Analog und Digitalsysteme GmbH 25 02 2014...

Reviews: