background image

4

Expert PDU energy 8310

Safety Advice

Safety Advice

1

The device must be installed only by qualified personnel according to the following installation and operating instructions. 

The manufacturer does not accept responsibility in case of improper use of the device and particularly any use of equip-
ment that may cause personal injury or material damage.
The device contains no user-maintainable parts. All maintenance has to be performed by factory trained service personnel.
Check if the power cord, the plug and the socket are in proper condition.
The device can be connected only to 230V AC (50 or 60 Hz) sockets.
Always connect the device to properly grounded power sockets.
The device is intended for indoor use only. Do NOT install them in an area where excessive moisture or heat is present.
Because of safety and approval issues it is not allowed to modify the device without our permission.
Please note the safety advises and manuals of connected devices, too.
The device is NOT a toy. It has to be used or stored out or range of children.
Packaging material is NOT a toy. Plastics has to be stored out of range of children. Please recycle the packaging materi-
als.
In case of further questions, about installation, operation or usage of the device, which are not clear after reading the ma-
nual, please do not hesitate to ask our support team.

Description

2

The

 Expert PDU energy 8310

 is a multiple socket outlet with CEE 7/4 sockets (model 

8310

) or 

 IEC C13

 sockets (model

8310-1

). It has a LCD display and can be connected to an Ethernet network. Integrated in the device is a Web server and an

SNMP server to enable remote retrieval of measurement data. In response to an adjustable threshold syslog messages,

emails and SNMP traps can be sent.

Features

Measurement of current, voltage, phase angle, power factor, frequency, active power, apparent power and reactive power

2 power meter, a counter counts continuously, the other counter is resettable

Backlit LCD Display

Quick and easy Plug & Play installation

Simple and flexible configuration via Web browser or Windows program

Platform independent operation via web browser

Syslog support

SNMP support (SNMPv1, SNMPv2c)

E-mail support (SMTP)

Firmware update via Ethernet during operation

Developed and manufactured in Germany

Hardware

3

Content of delivery

3.1

The delivery includes:

Expert PDU energy 8310

CD-ROM and manual

Installation

3.2

1. Insert the plug of the AC power cord into an outlet. The device reboots and is ready after a few moments. The display and

the status LED should be lit.

2. Connect your network to the Ethernet port of the 

Expert PDU energy 8310

.

3. Attach up to seven loads to the CEE 7/4 sockets (or IEC sockets for 8310-1) of the 

Expert PDU energy 8310

.

Summary of Contents for Expert PDU Energy 8310 Series

Page 1: ...2014 Gude Analog und Digitalsysteme GmbH Manual Ver 1 1 0 valid from Firmware Ver 1 1 1 Expert PDU Energy 8310 Series...

Page 2: ...ith your smartphone the important operating figures of your server and rack environment like sensor values max min energy consumption as well as state of inputs and outputs with watchdog functions In...

Page 3: ...k settings with GBL_Conf 7 4 3 Configuration via webinterface 4 3 1 Configuration IP Address 7 4 3 2 Configuration IP ACL 8 4 3 3 Configuration HTTP 9 4 3 4 Configuration Sensors 10 4 3 5 Configuratio...

Page 4: ...re not clear after reading the ma nual please do not hesitate to ask our support team Description 2 The Expert PDU energy 8310 is a multiple socket outlet with CEE 7 4 sockets model 8310 or IEC C13 so...

Page 5: ...s informations and statistics are available on the display Each time you press the but ton a new page is shown on the LCD display 227V 0 0A 0W 0 000kWh This is the usual energy view On the top line is...

Page 6: ...via the web interface Network settings with GBL_Conf 4 2 For changing the network properties manually the program GBL_Conf exe is required This tool is available for free on our website www gude info...

Page 7: ...ttp IP address of unit and press LOGIN To enter the configuration menu click on Configuration Tab Configuration IP Address 4 3 1 Hostname 4 3 1 1 Enter the hostname of the device The hostname is used...

Page 8: ...Netmask and a standard Gateway from this server If there is no DHCP server inside of your network we recom mend to deactivate this function For the changes to get valid a restart of the firmware is r...

Page 9: ...he firmware is required Require HTTP Password 4 3 3 2 Password protected access can be activated here In this case a user and an admin password have to be defined Pass words have a maximum lengths of...

Page 10: ...s up to 24 hours Hysteresis 4 3 4 3 Here you can specify a threshold that is reached after crossing a threshold in order to signal that falls below the threshold example Limit 10 C Action Output alarm...

Page 11: ...P communites like read write passwords SNMP v1 and v2 transmit the communities without encryption There fore it is simple to spy out these communities We recommend to use a DMZ or IP ACL 4 3 5 1 2 MIB...

Page 12: ...wnload SNMP MIB 4 3 5 6 Here you can download the MIB Configuration Syslog 4 3 6 Syslog messages are simple text messages transmitted to a syslog server using UDP Linux OS regularly have a syslog daem...

Page 13: ...1 Here you can activate the e mail function of the device E Mail server 4 3 7 2 Enter the e mail server e g mail gmx net Sender address 4 3 7 3 Enter the address the device should use when sending e m...

Page 14: ...the device status LED is slow the blinking In bootloader mode you can disable the password and IP ACL it is possible to use the program GBL_Conf exe to perform a firmware update and factory settings...

Page 15: ...will be loaded when the firmware of the device is re started the next time Support 6 In case of further questions about installation or operation of the device please have look at www gude info wiki...

Page 16: ...estimmter gef hrlicher Stoffe in Elek tro und Elektronikger ten RoHS on the restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS und dass die nachstehende...

Page 17: ...Expert PDU energy 8310 2014 Gude Analog und Digitalsysteme GmbH 25 02 2014...

Reviews: