57
Expert Power Control 8221/8226
© 2021 GUDE Systems GmbH
Specifications
settable
Resettable Forward Reactive Energy counter.
epc8221RevEnergyActive
.56.1.5.1.2.1.20.x
Gauge32
RO
Reverse Active Energy counter.
epc8221RevEnergyReactive
.56.1.5.1.2.1.21.x
Gauge32
RO
Reverse Reactive Energy counter.
epc8221RevEnergyActiveReset-
table
.56.1.5.1.2.1.22.x
Gauge32
RO
Resettable Reverse Active Energy counter.
epc8221RevEnergyReactiveReset-
table
.56.1.5.1.2.1.23.x
Gauge32
RO
Resettable Reverse Reactive Energy counter.
epc8221LineSensorName
.56.1.5.1.2.1.100.x
OCTETS
RW
A textual string containing name of a Line Sensor
epc8221OVPIndex
.56.1.5.2.1.1.x
Integer32
RO
None
epc8221OVPStatus
.56.1.5.2.1.2.x
INTEGER
RO
shows the status of the built-in Overvoltage Protection
epc8221PwrSupplyIndex
.56.1.5.13.1.1.x
Integer32
RO
Index of Power Supply entries
epc8221PwrSupplyStatus
.56.1.5.13.1.2.x
INTEGER
RO
shows status of the Power Supply for each bank
epc8221NTPTimeValid
.56.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc8221NTPUnixTime
.56.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc8221NTPLastValidTimestamp
.56.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
epc8221SensorIndex
.56.1.6.1.1.1.x
Integer32
RO
None
epc8221TempSensor
.56.1.6.1.1.2.x
Integer32
RO
actual temperature
epc8221HygroSensor
.56.1.6.1.1.3.x
Integer32
RO
actual humidity
epc8221InputSensor
.56.1.6.1.1.4.x
INTEGER
RO
logical state of input sensor
epc8221AirPressure
.56.1.6.1.1.5.x
Integer32
RO
actual air pressure
epc8221DewPoint
.56.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
epc8221DewPointDiff
.56.1.6.1.1.7.x
Integer32
RO
difference between dew point and actual temperature (Temp -
DewPoint)
epc8221ExtSensorName
.56.1.6.1.1.32.x
OCTETS
RW
A textual string containing name of a external Sensor
4.5.2
Device MIB 8226
Below is a table of all device-specific OID 's which can be accessed via SNMP. In the
numerical representation of the OID the prefix " 1.3.6.1.4.1.28507 " (Gude Enterprise
OID) was omitted at each entry in the table to preserve space. The example for a com-
plete OID would be "1.3.6.1.4.1.28507.58.1.1.1.1". A distinction is made in SNMP OID
's in between tables and scalars. OID scalar have the extension ".0" and only specify a
value. In SNMP tables the "x" is replaced by an index (1 or greater) to address a value
from the table.
Name
OID
Type
Acc.
Description
epc8226TrapCtrl
.58.1.1.1.1.0
Integer32
RW
0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
epc8226TrapIPIndex
.58.1.1.1.2.1.1.x
Integer32
RO
A unique value, greater than zero, for each receiver slot.
epc8226TrapAddr
.58.1.1.1.2.1.2.x
OCTETS
RW
DNS name or IP address specifying one Trap receiver slot. A port can
optionally be specified: 'name:port' An empty string disables this slot.
epc8226portNumber
.58.1.3.1.1.0
Integer32
RO
The number of Relay Ports
epc8226PortIndex
.58.1.3.1.2.1.1.x
Integer32
RO
A unique value, greater than zero, for each Relay Port.
epc8226PortName
.58.1.3.1.2.1.2.x
OCTETS
RW
Summary of Contents for Expert Power Control 8221 Series
Page 2: ...2 Expert Power Control 8221 8226 2021 GUDE Systems GmbH ...
Page 5: ...Device Description ...
Page 13: ...13 Expert Power Control 8221 8226 2021 GUDE Systems GmbH Device Description ...
Page 14: ...Operating ...
Page 24: ...Configuration ...
Page 50: ...Specifications ...
Page 91: ...Support ...