5.3.4.1
Connecting 402
A
B
C
E
D
Fig. 5-6
Connecting 402
A
FlexxPump 402
D
Connector pin assignment
B
Connection plug for connecting cable
E
Hydraulic outputs
C
Socket of connecting cable
Connect the product as follows:
1
2
Screw the connecting cable to the connecting plug
3
Connecting cable
3.1
PIN 1: Input voltage 24 V DC, color: brown
3.2
PIN 2: without assignment (402)
3.3
PIN 3: Mass (GND), 0V, color: blue
3.4
PIN 4: Output signal, color: black
The product is connected
Commissioning
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US