The following example will help you understand the relationship between the
settings:
D003865
P2
P1
1
2
3
3
6
0
9
12
P2
P1
1
2
3
3
6
0
9
12
Fig. 6-2
Example: lubrication quantity
With a cartridge emptying time of 12 months and a lubrication quantity P2 =
1, 2666 lubrication cycles are carried out with 0.15 cm
3
of lubricant each.
With a cartridge emptying time of 12 months and a lubrication quantity P2 =
3, 888 lubrication cycles are carried out with 0.45 cm
3
of lubricant each.
Increase the value of P2 in order to lubricate less often with large amounts of
lubricant
Reduce the value of P2 in order to lubricate more often with small amounts
of lubricant
6.4.3
Minimum lubrication quantity
Splitters only function correctly if > 0.5 cm
3
of lubricant is produced at their
input per lubrication cycle.
Operation
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US
69