6.4.4
Setting the lubrication cycle
The lubrication cycle is set as follows by default:
Setting
Value
Emptying time of the cartridge P1
12 months
Table 6-4
Lubrication cycle: Factory settings for P1
Entire system
Value
3 lubrication points (e.g. EP, TMF,
TMO)
3
6 lubrication points (e.g. ZP)
4
4 lubrication points (e.g. X-axis FP)
3
Table 6-5
Lubrication cycle: Factory settings for P2
WARNING
Automatic startup
During work on the product, there is danger of the machine starting up auto-
matically. This can lead to severe or fatal injuries!
Before working in the danger area:
• Secure vertical axes (if equipped) against falling.
• Switch off the superordinate main power supply. Secure it against being
switched on again (main switch for the complete system)
• Before switching on the system again, make sure that no one is in the dan-
ger area
The ON indicator flashes only briefly. If you do not touch the active surface
with the magnetic pin during this time, then the FlexxPump automatically
starts a lubrication cycle. In this case, cycle the FlexxPump off and back on.
Operation
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US
70