7.3.1
Replacing the cartridge
Replace the cartridge if the malfunction message "Empty" appears.
For pump type 402B, replace the battery at the same time.
CAUTION
Danger from spring tension
The covering contains a spring with tension. The covering jumps up when
opened. This can lead to minor injuries!
Make sure that no extremities are in the danger area. Carefully remove the
covering.
CAUTION
Residual amounts in empty cartridges
Empty cartridges contain lubricant residues. Oils and greases are harmful to
the environment!
• Dispose of the cartridge in an environmentally friendly manner
Use only original Güdel cartridges. Never refill the cartridges.
Maintenance
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US
79