NOTE
Empty battery
A battery charge lasts for one cartridge only and for a maximum of 3 years
(P1 ≤ 36 months). An empty battery causes material damage to the entire
plant due to inadequate lubrication.
• Replace the battery simultaneously with the cartridge
• Use only Güdel batteries. Only then can a sufficient battery charge be
guaranteed.
• Immediately replace the battery when error message E3 appears
The FlexxPump contains a capacitor. The capacitor stores the supply voltage
for 30 seconds. Strictly wait for 30 seconds before attaching the plug to the
new battery. Only then will the capacitor be fully discharged and the error
message E3 is reset correctly.
>30s
ü
≤30s
û
A
B
Fig. 7-4
Replacing the battery 402B
A
Battery
B
Plug
Maintenance
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US
82