7.3.3
Checking the lubrication system
Start
End
Clean guideways and racks
Lubricate guideways and racks with lubricating spray
(material number 10406825)
Disconnect all hydraulic lines from the pump
Start the pump's lubrication cycle
Does lubricant flow
out at all hydraulic
outputs of the pump?
Connect all hydraulic lines to the hydraulic outputs
of the pump
Fill lines with lubricant, bleed
air from the lines, remove
kinks
Start the pump's lubrication cycle
Expose lubrication point
Remount lubrication point
Yes
No
Hydraulic line filled;
without air bubbles and
kinks?
Yes
No
Check the pumps voltage
supply and function and
correct if necessary
Replace lubricating element /
lubricating pinion if necessary,
then prelubricate
Lubricating element /
lubricating pinion
saturated with
lubricant and intact?
Yes
No
Does lubricant flow
out at lubrication
point?
Yes
No
Other lubrication
points available?
Yes
No
Start lubrication point check
I
II
III
IV
VI
V
VII
VIII
IX
X
XI
XII
Maintenance
OPERATING MANUAL Automatic lubrication system