Replace the cartridge as follows:
1
Remove the vent locking mechanism in the direction of the arrow
2
Switch off FlexxPump
3
Remove the covering by turning in the direction of the arrow
4
Remove empty cartridge
5
Only pump type 402B:
Replacing the battery
6
Remove the retaining cover from the new cartridge
7
Lubricate the O-ring slightly
8
Insert new cartridge (make sure the cartridge fits in properly)
9
Put on the covering and turn hand-tight in the direction of the arrow
10
Switch on the FlexxPump
11
Insert vent locking mechanism and secure
The cartridge is replaced.
7.3.2
Replacing the battery 402B
CAUTION
Leaking batteries
Battery fluids and their fumes are hazardous to the environment, corrosive
and poisonous! They cause injury to persons and damage to property!
Observe the following points:
• Make sure there is good ventilation in closed rooms before repairing leaks
• Wear safety goggles and gloves
• Prevent battery fluids from getting into the drinking water supply
• Use only dry cleaning cloths without detergents
• Dispose of batteries in an environmentally friendly manner
Maintenance
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US
81