7.3.4
Checking automatic lubrication system
Fig. 7-5
Inspect automatic lubrication system
Cleaning agents
mild universal cleaner free from aromatic compounds (e.g. Motorex OPAL
5000)
Table 7-7
Cleaning agents: Automatic lubrication system: Pump, lines, other components
Check the automatic lubrication system in accordance with the following ta-
ble.
Inspection
point
Description
Measures
Contamination
Check the components
for contamination:
• Pump
• Lines
• other components
Immediately clean away any
contamination
Loss of lubricant
Check system and its
surroundings for traces:
• Puddles of oil and oil
spills on the floor or
in the drip sheets
• Leaks, torn or
pinched lines
• Remove puddles of oil
and oil spills on the floor
or in the drip sheets
• Replace defective and
pinched lines
Function
Check function
Replace defective compo-
nents immediately
Table 7-8
Inspection table
Maintenance
OPERATING MANUAL Automatic lubrication system
FlexxPump 402 / 402B
90071992656444683_v9.0_
EN-US
89