Author: Alain Thurner
Created: 12/11/2009
Process owner: Martin Knuchel
Released: 16.03.2018 / Version 34
Page 3 of 3
Risikobeurteilung_EN_V34.xlsx
M
inor
M
oder
at
e
S
ev
er
e
Ra
re
Ofte
n
F
requent
A
B
C
D
E
F
G
H
I
J
K
L
M
1
4
10
1
2
3
The following should be
prevented:
F
loor
-m
ount
ed dr
iv
e ax
is
R
ai
sed dr
iv
e ax
es
Recommendation to avoid residual risks
Hazard analysis / risk analysis
Machine type: all modules with/without control system
A
ffec
ted per
son(
s)
C
or
res
pondi
ng oper
at
ing
m
ode
Triggering factor
Event
(worst case)
(without protective measures)
S
et
up /
C
hangeov
er
C
leani
ng
T
roubl
es
hoot
ing /
R
epai
r
M
ai
nt
enanc
e
Dis
as
se
m
bly
D
is
pos
al
Source of danger
E
xt
ent
of
the
dam
age
C
at
egor
y /
P
Lr
(
S
IL)
m
ini
m
al
Risk assessment / safety goals / protective measures / residual risks
1)
Solution suggested to the customer (cursive, Times New Roman)
Güdel solution (Arial)
S
af
et
y r
equi
rem
ent
ful
fil
led [
Y
/N
]
O
per
at
ing m
anual
Protective measures
(existing protective measures)
Danger
symbol
Safety goal
(negation of the event)
P
robabi
lit
y of
oc
cur
renc
e
R
is
k as
ses
sm
ent
(
<=
3;
4-
8;
9-
20;
>
20
Int
er
nal
as
sem
bl
y
Special operating modes
N
or
m
al
oper
at
ion
H
az
ar
d no.
Int
er
nal
c
om
m
is
si
oni
ng
Int
er
nal
di
sas
sem
bl
y
C
om
m
is
si
oni
ng at
the
T
rai
ni
ng at
the c
us
tom
er
T
rans
por
t
A
ss
em
bl
y at
the c
us
tom
er
Application area
1.31 x
x
x x x x x
x
x
Electrical hazard
Operator,
Maintenance
personnel,
Technicians
Touching the machine
Defective insulation
Improper el. installation
Unsuitable components
Someone suffers an electric shock
and is injured or killed as a result
x x
10 3/d Operating personnel or third
parties are injured by direct or
indirect electrical contact.
Only contact-protected components are to be used.
Before working on electrical installations, always disconnect the system (plug/main
switch) and double check.
Work on electrical installations, switch cabinets and devices may only be
performed by authorized technicians.
Control cabinet fuses
Work on electrical installations requires expertise and extra care.
x Y
1.32 x
x
x
Disruption of the energy
supply
Operator,
Maintenance
personnel
Power failure, lightning, interrupted
compressed air supply
Someone is surprised by the
unexpected movement and injured as
a result
x x
10 3/d The effects of a power failure
endanger the operator or third
parties.
The movement of the drives is mechanically limited in case the supply voltage fails
(mechanical limit stops and holding brakes).
The movement of the drives is braked if the supply voltage fails. The operator and
third parties are outside the danger area.
After a crash, defective elements of the mechanical limit stops
cannot necessarily be recognized immediately. The entire bumper
unit must always be replaced.
x Y
1.33
x
x
x
x
Disruption of the energy
supply
Setters
Power failure, lightning, interrupted
compressed air supply
Someone is surprised by the
unexpected situation and injured as a
result
x x
10 3/d The effects of a power failure
endanger the operator or third
parties.
The movement of the drives is limited by mechanical limit stops in case the supply
voltage fails. The drives have already been switched off in case of a power failure
(safety shutdown situation). The movement of the drives is braked in case of supply
voltage failure by the motor brake or holding brake in the drive train.
After a crash, defective elements of the mechanical limit stops
cannot necessarily be recognized immediately. The entire bumper
unit must always be replaced.
x Y
1)
Protective measures (comments):
The suggested solutions printed in italics are binding suggestions for achieving CE conformity.
We would like to point out, however, that before commissioning the plant, suitable protective measures must be implemented for all hazards to ensure CE-compliant use of the Güdel devices.
According to the CE Machinery Directive 2006/42/EC, these suitable protective measures, including all modifications, must comply with the "state of the art" and ensure the necessary safety
category. If not all protective measures are implemented for any reason or any protective measures supplied and/or installed by Güdel have been modified or not installed, Güdel will not commission
the plant and will not assume liability or provide a warranty relating to any resulting events.
Summary of Contents for MLB 1-3 V2
Page 4: ...Revision history OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 4 ...
Page 14: ...Table of contents OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 14 ...
Page 86: ...Operation OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 86 ...
Page 159: ...9 4 Maintenance schedules Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 159 ...
Page 160: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 160 ...
Page 162: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 162 ...
Page 164: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 164 ...
Page 166: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 166 ...
Page 170: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 170 ...
Page 172: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 172 ...
Page 174: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 174 ...
Page 176: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 176 ...
Page 178: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 178 ...
Page 180: ...Maintenance OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 180 ...
Page 206: ...Repairs OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 206 ...
Page 212: ...Decommissioning storage OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 212 ...
Page 217: ...13 Spare parts supply Spare parts supply OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 217 ...
Page 218: ...Spare parts supply OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 218 ...
Page 224: ...Spare parts supply OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 224 ...
Page 234: ...List of illustrations OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 234 ...
Page 238: ...List of tables OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 238 ...
Page 246: ...Index OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US 246 ...
Page 248: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 249: ...Hazard analysis Risk analysis Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 250: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 255: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 258: ...Technical data Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 259: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 260: ...Layout Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 261: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 262: ...Spare parts lists Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 263: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 264: ...Options Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 265: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 266: ...Third party documentation Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...
Page 267: ...Appendix OPERATING MANUAL MLB 1 3 V2 881017611_v1 0_EN US ...