background image

                                                                                               

User Manual

 

 

32

  If necessary, manual NUC can be performed. To perform a NUC manually, keep button C 

depressed and then press button S when there is no menu or dialog box in live thermal 

image.  

  During the NUC the live image pauses temporarily, whilst a shutter is placed in front of the 

detector. 

  This process takes only a couple of seconds, however for best results, please ensure that 

camera is pointed at a low temperature uniform surface or the lens cap.

 

 

Focusing 

Thermal camera focusing   

There are two methods to adjust focus: manual and automatic. 

Before focusing, ensure the lens cap is uncovered and there is no menu or dialog box 

displayed in live thermal image.   

  To manually focus, aim the lens at the target and then move the joystick up or down.   

  To automatically focus, keep button F4 depressed till a frame appears in the image, aim 

the frame at the target and then release button F4, then the camera will automatically 

focus till getting a clear image of the target. 

Visual camera focusing 

Visual camera needs to be manually focused.   

  Press button F2 to switch from thermal image to visual image. 

  Rotate the visual focusing gear under the left side of lens at the front of the camera till 

getting a clear image of the target.   

Note:

 When the temperature difference between the target and its surroundings is not 

great, it is advisable to focus manually to get a clear image of the target.       

 

Setting the temperature range 

There are 3 methods available to set the temperature range: 

Auto1, Auto2

 and 

Manual. 

Summary of Contents for ThermoPro TP8S

Page 1: ...nology Co Ltd No 26 Shucheng Rd Hongshan District Wuhan 430070 P R China Telephone 86 27 8767 1991 Facsimile 86 27 8767 1927 Email overseas guide infrared com Internet www guide infared com Wuhan Guid...

Page 2: ...ting to electromagnetic compatibility and safety EMC directive 89 336 EEC Low voltage directive 73 23 EEC Copyright Wuhan Guide Infrared Technology Co Ltd 2007 All rights reserved worldwide No parts o...

Page 3: ...Parts Described 13 Attaching and Detaching the LCD Screen 21 Inserting Removing the SD Memory Card 21 Inserting Replacing the Battery 22 Battery Charging 24 Introduction to Buttons Joystick 26 Quick...

Page 4: ...ecautions must be adhered to at all times and must be considered in addition to any advised precautions issued at the relevant worksite or work area Keep the THERMOPRO TM TP8S IR Thermal Camera steady...

Page 5: ...adhered to at all times to ensure the safe use of this equipment Do not disassemble or attempt to open the battery under any circumstances Do not expose the battery to fire or high temperatures Do not...

Page 6: ...over of this User Manual or by email to the following addresses overseas guide infrared com Caution The THERMOPRO TM TP8S IR Thermal Camera does not incorporate any user serviceable parts Never attemp...

Page 7: ...S is another ingenious solution Wuhan Guide provides for professional IR thermographers around the world In a rugged compact and durable magnalium casing ThermoPro TM TP8S offers a wide assortment of...

Page 8: ...USB driver Guide IrAnalyser Software User manual Carry case strap Options Remote control handle Tele lens Wide angle lens Extended temperature range Technical Specification Imaging Performance THERMAL...

Page 9: ...ine Communication Touch Screen Present and receive operator s commands given by touch Remote Control Handle optional Respond as per operators operation Joystick Buttons Respond as per operators operat...

Page 10: ...n individual file consists of infrared image visual image voice annotation and text annotation if any Voice Annotation Up to 60 seconds per file Text Annotation Selected from preset texts Optional Len...

Page 11: ...sfer to PC RS232 communication Control of camera on PC Physical Characteristics Housing Magnalium Weight 0 85kg excluding battery LCD 1 1kg including battery LCD Size 186mm 106mm 83mm Standard Model T...

Page 12: ...agnalium camera casing raises reliability and operation easiness Robust on board analysis enhances operators efficiency productivity Hot shoe technology enables hot swap of the VGA LCD screen and non...

Page 13: ...zen images comprising radiometric data infrared image visual image voice annotation and text annotation can be saved into 2GB SD card or the built in flash memory in standard JPEG format Up to 60 seco...

Page 14: ...User Manual 14 1 VGA LCD touch screen 2 IR lens 3 Visual focusing gear 4 VGA video interface 5 USB2 0 interface 6 Battery door 7 Buckle for neck strap 8 Viewfinder 1 8 3 4 5 6 7 2 6 5 3 1 2 4...

Page 15: ...crophone to record voice annotation 3 F1 F4 function buttons and power button 4 Status display screen for power status USB SD card memory status 5 Joystick 6 Button S Button C and Button A 1 RS232 TV...

Page 16: ...User Manual 16 1 Laser locator 2 Visual camera 1 LCD mount 1 2 1...

Page 17: ...ontact pins at the LCD screen foot RS232 and TV Video cable Interfaces from the top down are respectively RS232 interface to PC TV Video interface to a TV Video display device TV Video RS232 interface...

Page 18: ...wn are respectively VGA video interface to the VGA interface on camera VGA interface to a VGA display device USB extension cable Interfaces from the top down are respectively Interface to the camera U...

Page 19: ...ctively Interface to be inserted to the power interface on camera plug to be connected to a socket or wall outlet Camera with cables from the top down and from left to right the camera is connected wi...

Page 20: ...ace and running the corresponding menu commands of Guide IrAnalyser software e g sub command Device Video of command Video under menu File you can view the live thermal video on PC control the camera...

Page 21: ...lizes hot shoe technology it is still advisable to switch off the camera before attaching or detaching the LCD screen Do not force the LCD screen into or out of the mount to avoid damage of the contac...

Page 22: ...es for the SD memory cards Ensure that saving or opening of images is complete before removing the SD memory card Do not use the SD memory card as a common removable disk for storing other information...

Page 23: ...n Keep the pop up button depressed release the battery then the battery will bounce and you can pull it from the camera When pulling the battery please still keep the pop up button depressed Replace a...

Page 24: ...steady Charging in an external battery charger Insert the battery into the battery charger This is done by aligning the end surface of the battery pack to the edge of the terminal shutter of this uni...

Page 25: ...e camera Additional Information All rechargeable batteries gradually lose their charge over time when they are left in storage If the battery is to be left in storage or for a period of non use a top...

Page 26: ...r menu options or to alter values of different parameters When there is a dialog box displayed in thermal image press the joystick to confirm selection and close the box When an option in the toolbar...

Page 27: ...tically in the two auto modes and can be adjusted manually in manual mode When there is no menu displayed in live zoomed thermal image press button A for an instant to select the temperature setup men...

Page 28: ...F4 then the camera will automatically focus till getting a clear image of the target Quick Start Guide Ensure that the battery is fully charged and the SD memory card is inserted in the camera Insert...

Page 29: ...image Press button S to freeze the live image Press button S to store the frozen image into SD memory card or built in flash memory of the camera Press button C to return to the live thermal image Usi...

Page 30: ...wn below is displayed with Guide logo and temperature setup menu lying at the right side status bar zoom bar memory media bar temperature display bar and time bar lying at the bottom Icon Significance...

Page 31: ...mperature and the maximum temperature of the current image Time bar Show the current time of the camera Non Uniformity Calibration NUC After powering on the camera and the boot screen flash disappears...

Page 32: ...thermal image To manually focus aim the lens at the target and then move the joystick up or down To automatically focus keep button F4 depressed till a frame appears in the image aim the frame at the...

Page 33: ...an instant to select the temperature setup menu at the right side of the image Then the menu flickers indicating you change its option values now Move the joystick up or down to toggle between its opt...

Page 34: ...to save the change and exit the menu Using the touch pen can also do the above operation Click the temperature setup menu with the pen first move the joystick left or right to change option values an...

Page 35: ...s the center temperature the value of M indicates the maximum scene temperature Static Temperature Measurement This method is available when there is no menu displayed in frozen or saved thermal image...

Page 36: ...played in the frozen or saved thermal image press button A for an instant to select the temperature setup menu at the right side of the image Move the joystick up or down to toggle between its options...

Page 37: ...then press Button S to freeze the live image Now the image status changes to be frozen Prompt Frozen is shown in the status bar under the image screen Pressing button S again can save the frozen image...

Page 38: ...al image display recording and playback of voice annotation adding text annotation histogram analysis etc When there is no menu displayed on the frozen image you can do static temperature measurement...

Page 39: ...lysis Do spot analysis on the frozen image Line analysis Do line analysis on the frozen image Area analysis Do area analysis on the frozen image Isotherm analysis Do isotherm analysis on the frozen im...

Page 40: ...ecording with the touch pen Or move the joystick up down left or right to toggle between the icons highlight the icon Start recording and then press the joystick to select it Now you can start recordi...

Page 41: ...notation with the touch pen Or move the joystick up down left or right to toggle between the icons highlight the icon Text annotation and then press the joystick to select it Then the annotation dialo...

Page 42: ...r in the status bar under the image screen when you try to store a new image If failing to save an image the prompt Save error will appear in the status bar under the image screen Replaying saved imag...

Page 43: ...ss button S to highlight the icon first and then press the joystick to select the icon To toggle between each icons of the file toolbar click them with the touch pen or press button S After highlighti...

Page 44: ...chosen either by clicking with the touch pen or by pressing button S to highlight first and then pressing the joystick to select or by moving the joystick left or right to highlight first and then pr...

Page 45: ...nd Histogram analysis respectively To do the left analysis listed above bring up the replay toolbar by clicking icon Guide at the right top corner of the screen with the touch pen or pressing the joys...

Page 46: ...oose it to open the previous image Replay text annotation Replay the text annotation added to the replayed image Exit command Exit the replay toolbar Spot line area and isotherm analysis is the same a...

Page 47: ...n Then the recorded text will be displayed in a dialog box on the image screen To close the dialog box choose the button OK by clicking it with the touch pen or pressing the joystick To exit the repla...

Page 48: ...not include text annotation Visual image The camera offers visual imaging function Visual image can be switched from its corresponding thermal image either in dynamic live status or static zoomed fro...

Page 49: ...front of the camera To switch to thermal image press button F2 again or press button C Picture in Picture This function is available in live or zoomed or frozen or saved images Bring up the main menu...

Page 50: ...matically switch to the mode Thermal image alone Pressing function button F2 again will switch to either the mode Picture in picture again or the mode Visual image alone To turn off this function brin...

Page 51: ...e camera offers a user friendly Windows style main menu The main menu is brought up on the screen by either clicking the icon Guide at the right top corner of the screen or pressing the joystick when...

Page 52: ...s are navigated by either clicking with the touch pen or moving the joystick left or right The highlighted option is confirmed by clicking with the pen or pressing the joystick To exit the menu system...

Page 53: ...ystick In frozen images bring up the frozen toolbar with the touch pen or joystick Click the icon Spot analysis with the touch pen to select it Or move the joystick to highlight the icon Spot analysis...

Page 54: ...and marked from A to H Clicking with the touch pen or pressing button S can toggle between them Temperature of the selected spot is displayed in the status bar under the image screen To move each spo...

Page 55: ...lable in the spot analysis Press button C to exit and return to the live or zoomed or frozen or save image Line Analysis Line Analysis can be performed on live or zoomed or frozen or saved images In l...

Page 56: ...then press the joystick to select it Then the cursor representing the starting point of the line is displayed in the image At this moment two methods are available to draw a line Method 1 Click and d...

Page 57: ...nfirm the line At the meantime the line profile is displayed in the image as well with the Max and Min temperature of the line displayed in the coordinate system The default coordinate system is a hor...

Page 58: ...an be performed on live or zoomed or frozen or saved images In live or zoomed images bring up the main menu select option Area under submenu File either by the touch pen or by pressing the joystick In...

Page 59: ...n them Temperature of the selected area as well as the temperature measurement type Minimum Average or Maximum will be displayed in the status bar under the image screen To move each area after select...

Page 60: ...by setting the value of sub option AreaFunc in option Analysis under submenu Parameter and then choosing button OK to confirm the setup It is possible to change the area number from 1 to 10 This is do...

Page 61: ...analysis with the touch pen to select it Or move the joystick to highlight the icon Isotherm analysis first and then press the joystick to select it In saved images isotherm analysis can be done when...

Page 62: ...et the minimum temperature of the isotherm band There are three isotherm colors to choose from This is done by setting the value of sub option IsoColor in option Analysis under submenu Parameter and t...

Page 63: ...am to be Off In frozen or saved images press function button F3 Then histogram of the image will be displayed at the right bottom corner of the image Pressing button F3 again will close the histogram...

Page 64: ...on Analysis Click option Analysis with the touch pen or press the joystick to select it Then the Analysis dialog box appears on the screen Clicking each option box with the touch pen or pressing butto...

Page 65: ...S first and then pressing the joystick IsoColor To choose a certain color for isotherm black white or green SpotNum To set the number of spots for spot analysis up to 10 spots are available AreaNum To...

Page 66: ...Moving the joystick left or right can toggle between each digit of the option values Emiss To set emissivity value between 0 01 and 1 00 RelHum To set relative humidity percentage value between 0 and...

Page 67: ...ues if the values contain several digits TempUnit To set the temperature unit for measurement degrees Celsius or Fahrenheit FrameAver To set the number of frames for frame averaging algorithm to freez...

Page 68: ...ss button C directly to cancel change Then the dialog box will be closed and the original image status will be resumed Option Function Click option Function with the touch pen or press the joystick to...

Page 69: ...minutes or 60 minutes No operation indicates in live or zoomed images there is no click on the VGA LCD screen no operation of joystick or buttons and no menu or dialog box displayed in the screen Pow...

Page 70: ...ing button No or pressing button C can give up the command To toggle between the buttons Yes and No press button S or move the joystick left or right To select them respectively click them with the to...

Page 71: ...ect button Start to start adjustment The a cursor appears at the left top corner of the screen click its center with the touch pen then a cursor appears in the center of the screen click its center wi...

Page 72: ...the pen and cursor will respond each other accurately Select button Exit or press button C to exit the interface and return to the live thermal image Note In the adjustment process improper adjustmen...

Page 73: ...it Then the copyright dialog box appears on the screen Press button C or press the joystick to close the dialog box and return to the live thermal image Powering off the camera To power off the camera...

Page 74: ...ve image Now you can view the live VGA video on LCD screen OLED viewfinder and the VGA display device VGA PAL output or VGA NTSC output When the camera and the TV video display device to be used are p...

Page 75: ...ra insert it into the card reader and then insert the reader to a USB2 0 interface of the PC Then PC will identify the card as a removable hard disk With the help of corresponding menu commands in Gui...

Page 76: ...menu in the live thermal image properly connect the USB interfaces of the camera to a USB2 0 port of your PC with the USB extension cable Microsoft Windows launches a Found New Device Wizard to guide...

Page 77: ...User Manual 77 Installation starts When getting to the step as shown below choose Continue anyway to proceed further...

Page 78: ...User Manual 78 Installation continues and finishes quickly Click button Finish...

Page 79: ...rosoft Windows automatically launches a further installation Choose Install from a list or specific location advanced and include the same folder you chose in the first installation Then Click button...

Page 80: ...User Manual 80 Installation starts When getting to the step as shown below choose Continue anyway to proceed further Installation continues and finishes quickly Click button Finish...

Page 81: ...umeration guideusb sys listed under Universal Serial Bus Controller it indicates the driver has been properly installed and you can transfer data from the camera to PC now The procedures to go to Devi...

Page 82: ...RS232 communication protocol is offered with the ThermoPro TM TP8S camera Through the protocol the camera can be conveniently controlled on PC at a remote monitoring place Installing the protocol y Cl...

Page 83: ...em launches an installation wizard Click button Next to go further y Choose Complete or Custom to install it in a certain manner If you choose Complete the installation directory will be C Program Fil...

Page 84: ...User Manual 84 Next to go further y The operating system is ready to install the protocol Click button Install to continue Then the installation will automatically progress...

Page 85: ...used Using the protocol y Before using the protocol please ensure the camera and your PC have been properly connected by the RS232 video cable offered together with the camera Then click on the short...

Page 86: ...ual 86 Parts Described y Three ports in PC for RS232 communication y Buttons for operating the camera y Display data that is corresponding to each operation and is exactly transmitted in PC Using the...

Page 87: ...e joystick to select this option and execute the command corresponding to it y While doing spot analysis pressing it will navigate through the spots y While doing area analysis pressing it will naviga...

Page 88: ...s moving the joystick up and down y When there is no menu displayed in live thermal image pressing them to zoom in or out the image continuously y While the main menu is displayed press them to toggle...

Page 89: ...mory or SD memory card y Press it to toggle between spots and areas while doing spot and area analysis on live or frozen or saved thermal images y Press it to switch between horizontal and vertical co...

Page 90: ...ght at the back of the camera shine steady Button F2 y Function is the same as button F2 on the camera y Press it in live frozen or saved thermal images to switch to visual image Button F3 y Functions...

Page 91: ...defective Replace battery Image is blurry The target is not in focus Adjust focus Brightness and contrast are inappropriate Adjust Tmin and Tmax Visual image is blurry The target is not in focus Adjus...

Page 92: ...calibration Emissivity What Is Emissivity The standard of radiation is blackbody radiation which exists in any enclosure whose walls are at a uniform temperature The shape of the enclosure and the wa...

Page 93: ...ng on the value of emissivity and the characteristics of the thermometer This temperature is known as the apparent or brightness temperature of the surface If the emissivity is constant this temperatu...

Page 94: ...are usually very wavelength dependent being higher at shorter wavelengths The appropriate settings for the ThermoPro TM TP8S IR Thermal Cameras are given in the following tables It must be remembered...

Page 95: ...90 Graphite 0 85 Alloys Soot 0 95 Brass 0 10 Cement Concrete 0 90 Oxidized 0 61 Cloth 0 85 Metals Aluminium 0 05 Oxidized 0 30 Chromium 0 15 Cobalt 0 18 Gold 0 02 Iron Steel 0 18 Oxidized 0 85 Lead 0...

Page 96: ...User Manual 96 Oxidized 0 11...

Reviews: