Section 3
TM9230A-C1-002 November, 2021
2 November, 2021
3-2
3.3
Measurement Ranges
Models in the 9230A series range in resistance values from 1 Ω to 5
µΩ
with full scale current capabilities
from 10 A to 5000 A respectively. Lead sets are available for all models that are designed to carry the
maximum shunt current rating. It is imperative that a sufficient number of suitably sized cables are used
to connect the shunts to the measurement system such that the thermal dissipation in the cables does
not ecessively add to that of the shunt itself. As well, where multiple connections are required it is
important that the symmetry of the connections horizontally and vertically is maintained around the
longitudinal centre line. The preceding considerations give each model in the series a very wide
dynamic range from virtually zero to full rated current.
With the use of the Model 92310 Forced Convection Unit full scale power levels at maximum specified
test currents vary from 90 W up to 125 W. When the shunts are used with natural air convection cooling
full scale power levels at the reduced maximum specified test currents vary from 22.5 W up to 31.3 W.
Performance specifications above the nominal 25 W are based on the use of forced convection to reduce
power coefficients.
Models may be utilized as precision resistance standards as low as 5
µΩ
when used at lower power
dissipation levels below a few watts. When maintained in a temperature controlled forced air or
circulating oil bath the shunt standards will provide the lowest uncertainties as ambient temperature
effects are substantially reduced.
The 9230A Series are designed for use with Direct Current. For AC Current
applications see our 7340 or 7350 Series of AC Shunts.