Hélicoptères Guimbal
SECTION 4
CABRI G2
NORMAL PROCEDURES
4-3
Note :
All castellated nut must be locked by cotter pin.
Lockwire must be tight.
Torque-seal marks must be intact.
Definition of Cabri G2 inspection stations
Station 1
:
Main rotor blades (each 3) :
Clean, particularly at leading-edge
Leading edge ........................... hand-check for damage or debonding
Tips bolts .................................................................. Check lockwiring
Right door hinges ...................................................................... Check
Door hinge safety pins (early models only) ............................. Installed
Windshield condition and cleanliness ........................................ Check
Sideslip string indicator .............................................................. Check
Lower windows condition and cleanliness ................................. Check
Landing light .............................................................................. Check
Pitot tube .......................................................... Cover removed, check
Static pressure port............................................. Plug removed, check
Front gear bow attachment ........................................................ Check
Left door hinges ......................................................................... Check
Door hinge safety pin (early models only)............................... Installed
4
1
5
2
3