Problem
Resolution
The logger seems to ignore the config.txt file and
use default settings.
Check that the config.txt file is properly formatted
and not corrupted. Each setting should occur on a
separate line.
Some IT organizations implement an automatic
encryption of all removable media devices. This
will encrypt the config.txt file and the logger will
not be able to access the file. Do not allow
encryption of the device.
The start time in the data file header is incorrect.
Initialize the RTC.
The time.txt file doesn't load to the RTC
Check that the date/time is correctly formatted
and the file name is “time.txt”. Windows may
hide the file extension so naming the file as
“time.txt” may actually be named “time.txt.txt”.
Check the Windows file explorer options the view
of regarding file extensions.
The logger is stationary but it registers 1g.
This is normal and indicates Earth's gravity is
operating correctly.
But the logger actually registers something other
than 1g when stationary.
The sensor will exhibit a slight offset error. Add
or subtract the appropriate amount to correct the
error.
I want to calibrate my X16 logger.
The logger does not have provisions for
implementing user-defined calibration coefficients
and any corrections must be performed post-
process.