background image

 

20

 

SHUTDOWN PROCEDURES 

 
Your spa must be emptied approximately every 1-3 months to ensure the spa water is clean and safe. 
Follow these step-by-step procedures whenever you need to empty your spa: 
 
The spa must be turned off. Simply turn off the heater switch or turn down the thermostat to the 
lowest setting. Turn off the pump. 
 
Connect a hose to the garden hose bib on the spa and open the garden hose bib valve. 
 
Drain the spa until the waterline is just above the bottom suction of your spa in the foot well. 
 

CAUTION! DO NOT

 let the pump run dry. IMMEDIATE DAMAGE may result which could void the 

warranty. 
 
Bail out the remaining water (using a Wet Dry Vacuum). 
 

LONG-TERM SHUTDOWN:

 If you wish to shut down your spa for an extended period of time, certain 

requirements must be met. A long-term shutdown may be due to an extended vacation or a 
mechanical failure. Due to possible cold weather, a number of special accessories may be 
neccessary to facilitate a long-term shutdown. These include: 
 

Sump Pump 

 Wet Dry Vacuum 

Small electric heater (MUST be used in cold weather) 

RV recreational antifreeze (MUST be used in cold weather)

 

 
If in winter, your spa pack fails and service is not immediately available to you, follow the above 
shutdown procedures in addition to the following: 
 
Drain the spa until absolutely no water remains. Use Wet Dry Vacuum if necessary to either blow all 
lines clear or to suck all lines clear. 
 
Place a small electric heater under the skirting of the spa. 
 
Unhook the suction and return lines by loosening both unions on the heater tube and drain lines as 
much as possible. Remove filter from canister. 
 
If possible, remove the spa control pack from the spa (see page 12) and bring inside for protection 
from freezing. If the spa is to be out of service for a long time, it may be necessary to squirt RV 
antifreeze into each jet to prevent any freezing. 
 
Vacuum out Jets, Pump, Heater, and Filter Canister with a Wet Dry Vacuum. 
 

WARNING!

 If these steps are not taken during cold weather when the spa is shut down, serious 

damage to the lines and spa may result! Freezing of the spa and/or equipment is not covered under 
warranty. If necessary, call the Gulf Coast 24-hour technical support hotline at (727) 573-9888. 

Summary of Contents for 10000/BOCA GRANDE

Page 1: ...COOL NIGHTS SERIES OWNER S MANUAL 11620 54th Street North Clearwater FL 33760 727 573 9888 www GulfCoastSpas com Premier Spas and Custom Wood Products ...

Page 2: ...pe Haze Englewood Rotunda and Boca Grande 11 PROGRAMMING FILTER CYCLES Cape Haze Englewood Rotunda and Boca Grande 12 FREQUENTLY ASKED QUESTIONS 13 TROUBLESHOOTING GUIDE 14 MAINTENANCE and CARE 15 SHUTDOWN PROCEDURES 16 SARASOTA SCHEMATIC 17 CAPE HAZE SCHEMATIC 18 ENGLWOOD SCHEMATIC 19 ROTUNDA SCHEMATIC 20 BOCA GRANDE SCHEMATIC 21 WARRANTY CLAIMS 22 IMPORTANT WARRANTY INFORMATION 23 2 3 3 5 6 9 10...

Page 3: ...RWISE This Manual Covers the COOL NIGHTS SERIES Sarasota Cape Haze Englewood Rotunda Boca Grande IMPORTANT SAFETY INSTRUCTIONS When installing your spa and using this equipment always follow basic safety precautions including the following READ AND FOLLOW ALL INSTRUCTIONS DANGER TO REDUCE THE RISK OF INJURY do not permit children to use this product unless they are closely supervised at all times ...

Page 4: ...r is provided on this unit to connect a minimum No 8 AWG 8 4mm2 solid copper conductor between unit and any metal equipment metal enclosures of electrical equipment metal water pipe or conduit if that item is located within 5 feet 1 5m of the unit DANGER RISK OF ACCIDENTAL DROWNING Extreme Caution must be exercised at all times to prevent unauthorized access by children To avoid accidents ensure t...

Page 5: ...r temperatures to 38 degrees C 100 degrees F Before entering a spa the user should measure the water temperature with an accurate thermometer The tolerances of water temperature regulating devices vary The use of alcohol drugs or medication before or during spa use may lead to unconsciousness with the possibility of drowning Persons suffering from obesity medical history or heart disease low high ...

Page 6: ...controls and equipment Consult your authorized dealer for more details ELECTRICAL SPECIFICATIONS IMPORTANT Qualified and licensed electricians must perform all electrical hookups The following specifications must be followed in order to ensure proper performance and safety CAUTION Failure to abide by specifications listed may result in damage to the equipment and may void the warranty ITEMS SPECIF...

Page 7: ...ST BE DISCONNECTED EN60335 1 and EN60335 2 60 230vac 50Hz 2x16A Single Phase IPX5 Spa Model Gulf Coast Spa Manufacturers Parts containing live parts supplied with safety extra low voltage not exceeding 12v must be inaccessible to a person in the bath Earthed appliances must be permanently connected to fixed wiring Parts incorporating electrical components except remote control devices must be loca...

Page 8: ...des and regulations in effect at the time of installation NOTE THIS The white Neutral wire from the back of the GFCI MUST be connected to an incoming Line Neutral The internal mechanism of the GFCI requires this neutral connection The GFCI will not work without it Load 120 Volts RED To Spa To Spa Load Neutral WHITE To Spa Load 120 Volts BLACK To Spa Pig Tail WHITE From GFCI Breaker Going To Neutra...

Page 9: ...dles are pulled out completely Slide Valve T Handle Union Check and tighten unions at each end of the heater tube CAUTION DO NOT use a wrench These are hand tightened unions and over tightening may cause damage to unions and gaskets which may not be covered under warranty Clean out the spa and remove any foreign material Gel Gloss Acrylic Polish or any type of soft paste wax is recommended for pol...

Page 10: ... valuable minerals All without using chemicals With the combination of the copper and zinc media in our exclusive AquaClara Water Management System our patented AquaClara Disc the Ozonator the Vortec Filtration Method and Microban the need for excessive chemicals is eliminated You will save hundreds of dollars annually with this easy to use system How it Works 1 Microban is an antimicrobial agent ...

Page 11: ...e power cord is it becomes damaged The power cord is equipped with a Ground Fault Circuit Interrupter located at the end of the power cord You always should test the GFCI before using the Sarasota First press the pump button on the console to turn on the Sarasota Second press the GFCI test button The Sarasota should turn off Third press the GFCI reset button The Sarasota should resume normal opera...

Page 12: ...he temperature The temperature can be adjusted in 1º increments between 41º F and 104º F 5º C and 40º C The new setting will remain on the screen for five seconds as a confirmation During this time the Temperature Set Indicator will be lit informing you that this is the desired temperature not the actual temperature After five seconds the display will return to the current temperature reading When...

Page 13: ... key is pressed within five seconds during programming the system will revert back to the monitoring mode If the pump and or light were turned on during programming turn them off The system will revert back to display the water temperature within five seconds Default System Operation When power is applied or there is a temporary loss of power the system will initiate its default programming The fi...

Page 14: ...14 14 ...

Page 15: ...r Press Blower key to turn Blower on at low speed Press a second time to turn Blower off A built in timer automatically turns pump off after 20 minutes unless it has been manually deactivated The Blower indicator lights up when Pump 1 is on Turning on Light Press Light key to turn Light on Press a second time to turn light off A built in timer automatically turns Light off after 2 hours unless it ...

Page 16: ... that the system has stopped filtering after 3 hours because water temp exceeds Set Point by more than 2 F 1 C If temperature cools down before the scheduled end of the cycle filtering will resume for the remainder of the programmed cycle Note After a power failure the filter cycle duration will return to its default value 6 hours In this case the first filter cycle will start 12 hours after power...

Page 17: ...F TOO MANY JETS AT THE SAME TIME THIS WILL CREATE BACKFLOW AND POSSIBLE DAMAGE TO YOUR SPA How do I maintain my cabinet California Redwood is virtually maintenance free A thin coat of linseed or cotton oil treatment applied twice a year will help maintain the cabinet s luster What is the insulation made of Gulf Coast uses a five step Thermazone process to fully insulate all of its hot tubs First t...

Page 18: ...d cycle 40 minutes beyond the last manual activation de activation NOTHING WORKS CAUSE Breaker has tripped Check and reset breaker If the problem persists check all electrical connections to ensure none are loose WATER WILL NOT HEAT CAUSE 1 Filter is dirty CAUSE 2 Thermostat is too low CAUSE 3 Fuse is blown CAUSE 4 Slide shut off valves are closed partially or completely Check and clean filter Che...

Page 19: ...b 2 Turn knob counterclockwise open until it stops 3 Pull knob firmly for full flow 4 Drain 5 Push knob back in place 6 Turn knob clockwise closed until it stops 7 Replace cap on drain bib SPA CONTROL PACK The spa support pack requires very little maintenance over its life span When changing the filter simply inspect the spa pack s self monitoring lights Wipe off dust from the spa pack this can in...

Page 20: ...acuum Small electric heater MUST be used in cold weather RV recreational antifreeze MUST be used in cold weather If in winter your spa pack fails and service is not immediately available to you follow the above shutdown procedures in addition to the following Drain the spa until absolutely no water remains Use Wet Dry Vacuum if necessary to either blow all lines clear or to suck all lines clear Pl...

Page 21: ...0 1627 6 5 POLY STORM ROTO JET LARGE FACE 212 0400 218 4010 711 4400 212 8147S 0 6 POLY STORM ROTO JET 212 0400 218 4010 711 4400 212 8017S 0 7 POLY STORM DIR JET 212 0400 218 4010 711 4400 212 8057S 6 8 POLY STORM TWIN ROT O JET LARGE FACE 212 0400 218 4010 711 4400 212 8177S 0 9 ADJ DIR MINI JET 212 0300 718 6960 711 6900 212 7927S 0 10 JUMBO STORM JET 711 0090 210 6817S 0 11 POWER STORM JET 212...

Page 22: ...67S 0 12 AIR CONTROL 660 3587 660 4407 2 13 HI FLO SUCTION 10 6764 GREY 1 14 WATERFALL 6 675 4007 1 15 LIGHT ASSEMBLY 3111 1 16 DYNO FLO SKIM FILTER W 35 SQ FT FILTER 510 6547HS 817 3501 1 17 FILTER LID 3003 1 18 35 SQ FT FILTER CARTRIDGE 817 3501 0 IF SUPPLY SEPARATELY 19 PILLOW 12 3012 3 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 90 X 90 GR 7021090090 1 23 SPA FL...

Page 23: ...18 6680 212 2067S 0 12 AIR CONTROL 660 3587 660 4407 3 13 HI FLO SUCTION 10 6764 GREY 3 14 WATERFALL 6 675 4007 1 15 LIGHT ASSEMBLY 3111 1 16 DYNO FLO SKIM FILTER W 35 SQ FT FILTER 510 6547HS 817 3501 1 17 FILTER LID 3003 1 18 35 SQ FT FILTER CARTRIDGE 817 3501 0 IF SUPPLY SEPARATELY 19 PILLOW 12 3012 3 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 90 X 90 GR 70210900...

Page 24: ... 212 2067S 0 12 AIR CONTROL 660 3587 660 4407 4 13 HI FLO SUCTION 10 6764 GREY 3 14 WATERFALL 6 675 4007 1 15 LIGHT ASSEMBLY 3111 1 16 DYNO FLO SKIM FILTER W 35 SQ FT FILTER 510 6547HS 817 3501 1 17 FILTER LID 3003 1 18 35 SQ FT FILTER CARTRIDGE 817 3501 0 IF SUPPLY SEPARATELY 19 PILLOW 12 3012 4 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 100 X 100 GR 7021100100 1 ...

Page 25: ...17 3501 0 IF SUPPLY SEPARATELY 19 PILLOW 12 3012 3 20 AROMATHERAPY INJECTOR 23041001 1 21 AROMA GARDENIA 23040500 1 22 ACRYLIC 100 X 100 GR 7021100100 1 23 SPA FLOOR DRAIN WITH VALVE 7381 7379 1 24 THERMOWELL 7380 1 25 SPA SIDE CONTROL OVERLAY G C 6070 6084 1 CS6230 VDS 26 SPA COVER BROWN 7558 1 92 X 92 X 6RC H22 27 WALL FITTING 212 1827 1 28 WATERFALL VALVE 600 4367 1 29 SUPER HI FLO SUCTION 640 ...

Page 26: ... affixed to the cabinet panel near the drain valve Serial Number Locations CONDITIONS OF WARRANTIES All warranties provided hereunder extend only to the original consumer purchaser of the spa if purchased and installed within the boundaries of the United States or Canada and terminate upon transfer of ownership from original consumer purchaser The warranties will not include any shipping cost and ...

Page 27: ...ship This limited warranty does not apply to any spa used for commercial rental or club purposes To ensure proper warranty performance you must notify Gulf Coast upon discovery of defect 727 573 9888 A Gulf Coast authorized service representative will correct the defect subject to the terms and conditions contained herein The service representative may assess reasonable travel charges during inspe...

Page 28: ..._________________________ Stamp _________________________ _________________________ Return Address 11620 54th St N Clearwater FL 33760 www GulfCoastSpas com ...

Reviews: