6
3) Check with your dealer on how to support the weight. In most cases, the best answer is a 4-inch
thick cement pad. However, there are many ways to support your spa. Please consult your spa sales
representative before constructing a base.
4) Be sure your spa will fit into the space you have chosen, and insure there is proper access into the
area of the spa for repairs if necessary.
5) Ventilation may be needed because of the humidity from the spa. In most cases, a Spa Hard Cover
is sufficient.
5) Check the load carry capabilities of the floor. Most homes meet the requirement of 125 pounds per
square foot.
6) Protect pump and all equipment from the weather. In many cases the equipment already is
installed and needs no further protection.
IMPORTANT!
When building a skirt or sinking a spa into a deck or ground, easy access must be
provided beneath the spa. This will ensure proper serviceability to the plumbing and equipment.
Please allow 36 inches. This is a minimum figure only! Consider your design carefully. The more
access the better. Make the access door in a logical place (i.e. near controls and equipment). Consult
your authorized dealer for more details.
ELECTRICAL SPECIFICATIONS
IMPORTANT!
Qualified and licensed electricians must perform all electrical hookups. The following
specifications must be followed in order to ensure proper performance and safety.
CAUTION!
Failure to abide by specifications listed may result in damage to the equipment and may
void the warranty.
ITEMS
SPECIFICATIONS:
Voltage
Breaker
Size:(amp/GFI)
Wire Size (Gauge)
Cape Haze-Single Pump
5.5 KW Heater
Single Pump With Blower 230 VAC
50 Amp Dedicated
6/3 With Ground
Cape Haze-Double Pump
Englewood, Rotunda, Boca
Dual Pumps 230 VAC
60 Amp Dedicated
6/3 With Ground
Sarasota-Single Pump
1.5 KW Heater 120 VAC
20 Amp Dedicated
12/3 Standard Size
5.5 KW Heater 230 VAC
50 Amp Dedicated
8/3 Standard Size
ALL SPAS WITH DUAL 5.0 HP PUMPS MUST BE WIRED WITH A 60 AMP BREAKER. FAILURE
TO DO SO WILL CAUSE EQUIPMENT DAMAGE AND WILL NOT BE COVERED UNDER
WARRANTY.
ALL SPAS MUST BE PROTECTED WITH AN OVER CURRENT PROTECTIVE DEVICE WITH
BUILT-IN GROUND FAULT CIRCUIT INTERRUPTER (GFCI) IN THE SERVICE PANEL.
CANADA/EUROPE:
CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT
CIRCUIT INTERRUPTER. ATTENTION: CONNECTER UNIQUEMENT A UN CIRCUIT PROTEGE
PAR UN DISJONCTEUR DIFFERENTIEL DE CLASS A.