60 Amps
Breaker Box
60 AMP GFCI
IMPORTANT
6 Gauge Wire
MUST
Be Used!
Power
Source
IN
IMPORTANT NOTE: Installation of
this GFCI-Circuit Breaker,
including ampere sizing and
selection of conductor size and
type, must be accomplished by a
qualified electrician in
accordance with the National
Electrical Code, or The Canadian
Electrical Code, and all federal,
state and local codes and
regulations in effect at the time of
installation.
NOTE THIS: The white Neutral wire from
the back of the GFCI MUST be connected
to an incoming Line Neutral. The internal
mechanism of the GFCI requires this
neutral connection. The GFCI will not
work without it.
Load 120 Volts (RED)
To Spa
To Spa
Load Neutral (WHITE)
To Spa
Load 120 Volts (BLACK)
To Spa
Pig Tail (WHITE)
From GFCI Breaker
Going To Neutral Bar
In Box
Ground (Green)
To Spa
Ground Bar Attached
To Box (GREEN)
INPUT & OUT
Load (RED)
INPUT
Load (BLACK)
INPUT
Load Neutral
(WHITE)
INPUT
Load Neutral Bar
Ground (GREEN)
INPUT
8