8
E l e c t r i c a l S p e c i f i c a t i o n s
Important –
Qualified and licensed electricians must perform all
electrical hookups. The following specifications must be followed in
order to ensure proper performance and safety.
WARNING:
Starting an incorrectly wired spa could cause
severe damage to the mechanical equipment or
even bodily harm. Have your licensed electrician
verify GFCI wiring with the schematics on page 10-
11 prior to starting the spa or call the technical
support line at (727) 573-9888.
Caution:
Failure to abide by specifications listed may result in
damage to the equipment and will void the warranty.
US/Canada:
All spas must be wired with a 50 Amp breaker. Failure to do so will
cause equipment damage and will not be covered under your
warranty.
All spas must be protected with an over current protective device
with built-in GFCI in the service panel.
Voltage
Breaker Size Amp/GFI
Wire size
Country
240V 60Hz 50 Amp dedicated
6/3 with Ground U.S. and Canada
230V 50Hz IEE Wire Regulation
3x4 mm
2
European Union
EUROPE:
WARNING:
Disconnect the electrical power before servicing.
Before obtaining access to terminals, all supply
circuits must be disconnected.
Avertissement:
Disconnecter du circuit d'alimentation
electrique avent l'entretien.
Summary of Contents for LX 11000
Page 13: ...11 European 1x32A Wiring Diagram Jumper L1 L2 L3 ...
Page 14: ...12 European 2x16A Wiring Diagram Jumper L2 L3 ...
Page 15: ...13 European 3x16A Wiring Diagram No Jumper ...
Page 48: ...46 Notes ...
Page 49: ...47 Notes ...
Page 50: ...48 Notes ...
Page 52: ...11620 54th Street North Clearwater FL 33760 727 573 9888 www GulfCoastSpas com ...