4.1 FITTING THE APPLIANCE
4.1.1 General
(a) The appliance should be handled carefully
to avoid damage and the recommended
method is shown on page 2 of this manual.
(b) The appliance should be mounted on
the 100mm high plinth supplied with
the appliance to facilitate the pipework
connections at the front of the appliance.
(c) When using push fit connectors with the
flexible hose kits it is important to check
that they are compatible. We currently
recommend push fit connectors from the
following manufacturers:
• Hepworth –Hep
2
O BiTite
• John Guest – Speedfit
• Yorkshire – Tectite
(d) The installer must check and confirm the
suitability of any other types of push fit
connectors. The gas connection, and on the
OV model the combined cold feed and open
vent connection are located at the top of the
appliance. (See figures 3.3, 4.1, 4.2 and 4.3) All
other connections are located at the bottom
front of the appliance (figure 4.1).
(e) The appliance is supplied with 2 metre long
10mm² 3-core flexible cable for connecting
to the fixed wiring in the dwelling. The fixed
wiring to the appliance must incorporate
a double pole isolator with at least 3mm
contact separation at all poles. This 45A
double pole isolator must be within 2m of
the appliance and the appliance mains cable
must be wired to this isolator.
4.1.2 Access to the Appliance
(a) Remove front panel by unscrewing the two
screws on the left hand and right hand sides
at the top of the appliance. Disengage the
front panel from the top panel by lifting
and pulling it forward at the top. Lift the
front panel to disengage it from the bottom
edge.
(b) The top panel can now be removed by
gradually lifting it at the front and pulling it
forward.
Figure 4.1 Connections at the top
Figure 4.2 Open vented model connections
Figure 4.3 Sealed system model connections
INSTALLATION AND WIRING
Auto
Air Vent
Gas
Connection
Feed and
Open Vent
Flue
Connection
Figure 4.1 Connections at the top
Heating
flow
Cold water
mains inlet
Hot water
outlet
Condensate
drain
Heating
return
Figure 4.2 Open Vented Model Connections
Heating
flow
Cold water
mains inlet
Hot water
outlet
Condensate
drain
Heating
return
Figure 4.3 Sealed System Model Connections
Tundish
discharge
Summary of Contents for GS A-Class 12/OV
Page 39: ...Supplied By www heating spares co Tel 0161 620 6677 Page 39 GULFSTREAM A CLASS ...
Page 40: ...Supplied By www heating spares co Tel 0161 620 6677 Page 40 ...
Page 41: ...Supplied By www heating spares co Tel 0161 620 6677 Page 41 GULFSTREAM A CLASS ...
Page 42: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 43: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 44: ...Supplied By www heating spares co Tel 0161 620 6677 ...