COMMISSIONING
Table 5.7
Locking error name
Internal
error
number
Remarks
Eh
backup
enabled
E2PROM_READ_ERROR
0
Control error
No
SAFETY_RELAY_ERROR
1
Control error
No
E2PROM_ERROR
2
Control error
No
WRONG_EEPROM_SIGNATURE
3
Control error
No
ROM_ERROR
4
Control error
No
RAM_ERROR
5
Not used (control is reset)
-
20MS_ERROR
6
Not used (control is reset)
-
41MS_ERROR
7
Not used (control is reset)
-
STACK_ERROR
8
Not used (control is reset)
-
GV_RELAY_ERROR
9
Control error
No
OVERHEAT_ERROR
10
Sensor error, overheat detected
No
OVERHEAT_DIFFER_ERROR
11
Sensor error, overheat sensors differ
No
T_MAX_LOCK_ERROR
12
Burner error (overheat)
Yes
FLAME_OUT_TOO_LATE_ERROR
13
Burner error
Yes
FLAME_ERROR_1
14
Burner error
Yes
IGNIT_ERROR
15
Burner error
Yes
TOO_MANY_FLAME_FAILURES
16
Burner error
Yes
15MS_ERROR
17
Not used (control is reset)
-
FLAG_BYTE_INTEGRITY_ERROR
18
Control error
No
AD_HI_CPL_ERROR
19
Control error
No
AD_LO_CPL_ERROR
20
Control error
No
REGISTER_ERROR
21
Control error
No
FAN_ERROR
22
Not used
Yes
BOILER_RELAY_ERROR
23
Not used
Yes
EH_RELAY_ERROR
24
Not used
No
Table 5.8
Blocking error name
Internal
error
number
Remarks
Eh
backup
enabled
REFHI_TOO_LO_ERROR
25
Control error
No
REFHI_TOO_HI_ERROR
26
Control error
No
REFLO_TOO_LO_ERROR
27
Control error
No
REFLO_TOO_HI_ERROR
28
Control error
No
WD_COMMUNICATION_ERROR
29
Control error
No
PHASE_DETECTION_ERROR
30
Control error
No
50HZ_ERROR
31
Control error
No
RESET_BUTTON_ERROR
32
Control error
No
APPLIANCE_SELECTION_ERROR
33
Control error
No
OVERHEAT_1_ERROR
34
Sensor error
No
OVERHEAT_2_ERROR
35
Sensor error
No
GP_LOST_ERROR
36
Burner error / Control error
Yes
T_OVERHEAT_1_OPEN
36
Sensor error
No
T_TANK_BOTTOM_OPEN
38
Sensor error
Yes
SPARE_BLOCK_ERROR_39
39
Not used
-
T_FLUE_OPEN
40
Sensor error
Yes
SPARE_BLOCK_ERROR_41
41
Not used
-
T_TANK_MIDDLE_OPEN
42
Sensor error
Yes
SPARE_BLOCK_ERROR_43
43
Sensor error
Yes
T_OVERHEAT_2_OPEN
44
Sensor error
No
T_OVERHEAT_1_SHORTED
45
Sensor error
No
T_TANK_BOTTOM_SHORTED
46
Sensor error
Yes
SPARE_BLOCK_ERROR_47
47
Not used
-
T_FLUE_SHORTED
48
Sensor error
Yes
SPARE_BLOCK_ERROR_49
49
Not used
-
T_TANK_MIDDLE_SHORTED
50
Sensor error
Yes
SPARE_BLOCK_ERROR_51
51
Not used
Yes
T_OVERHEAT_2_SHORTED
52
Sensor error
No
FLAME-ERROR-2
53
Burner error
Yes
When the T_TANK_MIDDLE sensor is defective store heating is still possible.
Because the demand for store depends on this sensor, in this case the
T_OVERHEAT sensor can be used instead of T_TANK_MIDDLE to determine if
demand for store is active.
Table 5.9
DHW Warning error names
Internal
DHW error
number
Remarks
DHW
handling
enabled
DHW_T_DHW_OUT_OPEN
0
DHW error
Limited
DHW_T_DHW_IN_OPEN
1
DHW error
Limited
DHW_T_DHW_OUT_SHORTED
2
DHW error
Limited
DHW_T_DHW_IN_SHORTED
3
DHW error
Limited
There are no locking errors for DHW. If a DHW_ERROR occurs both the error
- and ok indicators will flash on the display to indicate a non fatal error.
(d) Ensure that both space heating and hot water are switched
off at the programmable room thermostat.
(e) Switch on the mains supply. The controller will initialise
and green LED on the front panel will illuminate.
(f) Switch on hot water demand at the programmable room
thermostat. The bars D1.6 and D1.2 (figure 5.2) will come on
and the boiler will go through the ignition sequence and
then start heating the store. During the ignition sequence,
the yellow LED on the front panel will flash and when the
burner is on, the yellow LED will be permanently on.
(g) If the burner fails to ignite the controller will automatically
restart the ignition sequence and will make 5 attempts to
ignite the burner. If a lock out condition occurs, it will be
indicated by a flashing red LED on the front panel. The lockout
can be cleared by pressing button B1 on the front panel.
(h) Measure and record the inlet gas pressure in the ‘Benchmark’
logbook.
Table 5.10 Tank Temperature Warning Table
No.
Definition
Store Heating
0
T_Tank_Top/Middle_Open
limited
1
T_Tank_Bottom_Open
limited
2
T_Tank_Top/Middle_Shorted
limited
3
T_Tank_Bottom_Shorted
limited
4
EB_Failure
limited
Summary of Contents for GS A-Class 12/OV
Page 39: ...Supplied By www heating spares co Tel 0161 620 6677 Page 39 GULFSTREAM A CLASS ...
Page 40: ...Supplied By www heating spares co Tel 0161 620 6677 Page 40 ...
Page 41: ...Supplied By www heating spares co Tel 0161 620 6677 Page 41 GULFSTREAM A CLASS ...
Page 42: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 43: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 44: ...Supplied By www heating spares co Tel 0161 620 6677 ...