background image

SAFETY & PRECAUTION

 2

GROUNDING METHODS

Because this unit must be connected to a circuit with a ground-fault circuit interrupter (GFCI), DO NOT use a grounding 
adapter.
The use of a grounding adapter is prohibited in Canada by Part I of the Canadian Electrical Code.

GROUNDING INSTRUCTIONS

This appliance must be plugged into an outlet equipped with a ground-fault circuit interrupter.  The ground-fault interrupter 
can be in the out-let shown in illustration A or in the circuit breaker (fuse) box.  If your outlet or circuit breaker (fuse) box is not 
equipped with a ground-fault interrupter, you must have your electrician install one.

In the event of an electrical short-circuit, the ground-fault circuit interrupter will turn off the electrical power to the unit 
immediately, greatly reducing the likelihood of serious injury.  This appliance is for use with a nominal 120-volt circuit and has 
a grounding plug that looks like the plug illustrated in the sketch. The outlet must be properly installed and grounded in 
compliance with all local codes and ordinances.

If it is necessary to use an extension cord, use only a three-wire extension cord that has a three-blade grounding plug and a 
three-blade grounding plug and a three-slot receptacle that will accept the plug on the appliance.  Replace or repair a 
damaged cord.

OPERATION AND USE INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS.

1.    IMPORTANT!  At the end of the day, ALWAYS turn the main power OFF!
2.    DANGER:  To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised
       at all times.
3.    CAUTION:  This unit should not be used by persons with open wounds, cuts or sores on their feet or legs, or by
       persons with poor circulation, or by persons with heart conditions.  If in doubt, the client should consult with his
       or her physician.
4.    Use this unit only for its intended use as described in this manual.  Do not use attachments not recommended
       by the manufacturer
5.    Do no operate with a damaged cord or plug.  If unit is malfunctions or is damaged in any
       manner, contact an authorized service representative for examination or repair.
6.    Never drop or insert any objects into any opening.
7.    Do not block jets during pedicure operation.
8.    Water temperature should be checked before use.  Water temperature should never exceed 100 degrees
       Fahrenheit.
9.    Never bring any electrical devices into the unit or operate electrical devices near it.
10.  The unit must be connected to a supply circuit that is protected by a ground-fault circuit interrupter (GFCI).
11.  Connect the unit only to a properly grounded outlet.  See grounding instructions.
12.  Close supervision is necessary when the unit is used by, on or near children or invalids.

COMPLIANCE  WITH  LOCAL  CODES  OR 
INSPECTIONS  IS  THE  RESPONSIBILITY  OF 
THE  PURCHASER  AND/OR  INSTALLER

Summary of Contents for Mini Lavender

Page 1: ...cations are subject to change without notice 2011 All rights reserved PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE OWNER MANUAL Cleanjet Gulfstream Inc Gulfstream Inc are trademarks of Mini Lavender Patent D610697 D600950 ...

Page 2: ...Table of Contents Safety and Precautions INSTALLATIONS Jet Assembly Plumbing Connections 1 2 Identifying Parts 3 4 5 6 Warranty Service 10 Owner Manual Operations and Use Cleaning Maintenance 7 8 9 ...

Page 3: ...ay cause severe damage to the unit as well as possible serious injury to the person BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING 1 Read and follow all instructions 2 DANGER To reduce the risk of injury do not permit children to use this unit unless they are supervised at all times 3 Use this unit only for its intended use as described in this manual Do not use attachments th...

Page 4: ...ir a damaged cord OPERATION AND USE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS 1 IMPORTANT At the end of the day ALWAYS turn the main power OFF 2 DANGER To reduce the risk of injury do not permit children to use this unit unless they are closely supervised at all times 3 CAUTION This unit should not be used by persons with open wounds cuts or sores on their feet or legs or by persons with poor ...

Page 5: ...table Footrest Wheel Lock Jet Control Laminated Wood Grain Base La Mini Lavender Mini Lavender Dimension Length 22 56 cm Width 19 1 4 49 cm Height 21 43 cm Footrest Up 26 66 cm Pedi Bowl Dimension Wide 19 5 49 5 cm Height 18 1 4 46 5 cm Front Jet Unit ...

Page 6: ... Plate Anchors located on tub bowl wall Impeller Housing Top Plate Wall Ball Bushing Anchor Pegs Jet Unit Components To install the jet unit Assemble all jet unit components in order as before removal snap the jet unit onto the anchor pegs located on tub bowl wall securely Note All jet unit components must be assembled in sequence of order to avoid malfunction Screws Please call manufacturer for r...

Page 7: ... gently pull out the jet unit as shown in Fig 3 from the bowl and pull up the plastic liner To avoid risk of infection disease discard the liner after each use Heavy Soft plastic liner Fig 1 Removable Pedi Bowl Fig 3 Poly Liner Installation Fig 2 Jet Unit Heavy Soft Plastic Liner Pedi Bowl Wall Bottom Pedi Bowl Jet Designation ...

Page 8: ...d to supply power to the unit The roller back massage chair uses a 115V A C supply 3 Spa unit should stand securely on level floor with the wheel lock on when in use There is no drain connection with the spa Simply lift up the pedi bowl and discharge When using soft liner simply pull FAILURE TO ANCHOR THE BASE MAY RESULT IN PERSONAL INJURY OR DAMAGE TO THE UNIT DAMAGE AS A RESULT WILL VOID THE WAR...

Page 9: ...l up the liner and discard the water Control Panel OPERATIONS USE 7 BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING 1 Read and follow all instructions 2 DANGER To reduce the risk of injury do not permit children to use this unit unless they are supervised at all times 3 Use this unit only for its intended use as described in this manual Do not use attachments that are not recom...

Page 10: ...hirlpool for 15 minutes drain and then wipe dry with clean soft cloth NOTE Cleaning or sanitizing is NOT disinfecting According to the Centers for Disease Control and Prevention CDC and the US Environmental Protection Agency EPA disinfecting occurs only when there is a reduction of pathogenic microbes at 99 999 Sanitizing is only a reduction of 99 9 Cleaning of whirlpool pedicure spas requires sur...

Page 11: ...on top of the Magnet and the Back Plate so that the tab is slightly left from the top Turn the Top Plate clockwise until you hear a click sound Note there are 3 pegs on the back of the Back Plate the pegs which has small holes 1 18 of an inch should be aligned with the Top Plates tab after the click sound 6 Remount the Magnet Jet onto the pedicure bowl by aligning the pegs so that the tab is at th...

Page 12: ...of plastic surfaces due to exposure and or the use of harmful cleaning agents or chemicals 3 Staining fading or discoloration caused by improper or poor water additives not related to the maintenance of proper water are not covered by this warranty 4 Staining fading or discoloration of the seat armrests or footrests 5 Freight damage misuse neglect accident natural disaster and abuse 6 Unauthorized...

Page 13: ...ns are subject to change without notice 2011 All rights reserved Manufacturer of Acrylic Bath Whirlpool Pedicure Foot Spas Gulfstream Inc Cambridge Ontario Canada N1R 5X5 Tel 519 622 0950 Fax 519 622 6926 www gulfstreaminc com ...

Reviews: