78
Technical data
79
Technical specification
Model
Q12
Q15
Q20
Q30
Q30-3P
Heat output
1
kW
4.0
4.3
6.0
8.0
8.0
Heating capacity
2
m
3
10-25
20-35
30-45
40-60
40-65
Input power
kW
1.0
1.0
1.4
1.8
1.8
Operating voltage
V~50Hz
230V 1N
400V 3N
Operating current
3
A
4.5
4.7
6.3
8.0
3.1
Fuse size, Type C
A
10
16
3x10
Coefficient of performance,
COP
4.0
4.3
4.3
4.5
4.5
Refrigerant quantity (R410A)
kg
0.75
0.55
0.8
1.0
1.0
Compressor
Rotary compressor
Expansion
Capillary tube
Heat exchanger
Titanium heat exchanger
Fan motor
AC motor
Cabinet
Grey painted steel cabinet
Noise level (at 1 m)
dB(A)
48
50
52
53
53
Water connection
mm
50 mm
Nominal water flow
m
3
/h
1.8
2.3
2.8
5.7
5.7
Pressure drop at nominal
flow
bar
0.08
0.04
0.02
0.04
0.04
Pressostat breaking value HP
bar
44 (switch closes again at 32 bar)
Pressostat breaking value LP
bar
0.2 (switch closes again at 1.5 bar)
Height
mm
584
584
605
605
605
Width
mm
791
791
954
954
954
Depth
mm
300
300
372
372
372
Weight
kg
39
39
55
58
58
1
The heat output and coefficient of performance are specified at an outdoor temperature of 15 °C, relative
humidity of 70 % and a pool temperature of 26 °C, in accordance with the French pool heat pump standard
NF 414.
2
Heating capacity should be regarded as guide values for an insulated pool covered at night. The models are
primarily designed for use during the period May to September which is a normal pool season.
3
The operating current is specified at an outdoor temperature of 15 °C, relative humidity of 70 % and a pool
temperature of 26 °C. The operating current may vary depending on the above conditions.