Section 5 

Installation

 

 

Installation 

 

 

 

 

 

 

 

 

 

 

 
Unpacking 

 
Check that all the material has been delivered intact.  Gunnebo does not accept any responsibility for 
damage that occurs by transportation or installation. 
 
Electrical  installation  must  be  carried  out  by  authorised  staff.    The  placing,  installation  and 
specifications of all cables must comply with the instructions given in this document. 
 
Gunnebo  does  not  accept  responsibility  for  any  injury  or  damage  incurred  due  to departure  from  the 
instructions in this Technical Manual. 
 

Tools Required 
 

 

Industrial hammer drill 

 

Concrete drill bit 12mm 

 

Socket 17mm AF (x2) 

 

Torque wrench 

 

8mm Spanner 

 

Metric Allen Keys (1 x set) 

 

Please read carefully before commencing the installation 

 

Site Preparation 
 

The following illustrations show the site preparation details that are required for the various units.

 

 

Concrete to BS 5328:1997 specifications - Type ST5 
The base must be flat and level to +/-5mm over the GlasStile GSS area. 
The  base  must  be  laid  with  under  floor  conduits  with  a  minimum  diameter  of  20mm  rising  in  the 
positions  indicated  on  the  particular  illustration,  to  accommodate  the  cables  for  power  supplies  and 
any remote control devices. 
 
It is recommended that the mains power to the unit passes through a Residual Current Circuit Device 
for maximum safety. 
 
A  second  conduit  should  be  provided  for  any  remote  control  cables  that  may  be  required.  On  units 
controlled  by  pushbuttons  or  footswitches  a  four-core  cable  having  a  minimum  conductor  size  of 
0.5mm sq. should be laid and a 1.5m tail left. (Screened cables are NOT normally required) 
 
For  units  that  are  to  be  controlled  by  Card  Access  or  similar  it  is  recommended  that  Gunnebo 
Technical Personnel are advised prior to starting the installation routines. 
 

Installation Kit 
 

Item 

Quantity 

 

 

Rotor Assembly

 

Cladding Kit 

Top Cap 

Cladding Cover 

Glass Panel 

Anchor Bolts (72544001) 

 

Summary of Contents for GlasStile GSS

Page 1: ...CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 GlasStile GSS Installation Operation and Maintenance Manual...

Page 2: ...CCEC OM Manual GlasStile GSS 1 6 EN 07 2009...

Page 3: ...the GlasStile GSS 11 Reception Control Pass Left Right Option 11 Operating Modes 12 Reset 12 Remote Push Button Activation Optional 12 Safety 12 Blocking the GlasStile GSS 12 Power Failure 12 Fire Ala...

Page 4: ...EN 07 2009 SECTION 6 MAINTENANCE 27 General Care 27 Brake Adjustment 29 Encoder Replacement 29 Replacing the Control Card 29 Trouble Shooting 29 SECTION 7 SPARE PARTS 31 Recommended Spare Parts 31 SEC...

Page 5: ...s fully aware of the danger involved and who have taken adequate precautions and training Mechanical Warnings Safety systems and controls such as interlocks covers and guards must not be overridden or...

Page 6: ...Warnings must be followed precisely They are given to avoid injury or death Cautions Are for conditions that may cause damage to equipment or may spoil work The instructions given in Cautions must be...

Page 7: ...ioning 8 Floor Drilling Glass Panel Installation Rating 1 Cleaning Who is at Risk Engineers or Site Personnel Hazard Mis use of Cleaning Fluids Current Controls Compliance with COSSH regulations Ratin...

Page 8: ...ontrols Protective Equipment must be worn Glass Panel Installation Who is at Risk Installation Engineer Hazard Glass Breaking Incorrect handling techniques Current Controls Protective Equipment must b...

Page 9: ...econds can be connected to the gate An acknowledgement impulse of completed rotations is given before or after each rotation is started complete The status of the gate is indicated on its volt free al...

Page 10: ...nical parts 304 grade Stainless Steel Glass Wing 10mm Toughened Glass Power Failure Gate Rotates freely with any power loss or emergency signal Power Supply Voltage 110 230 VAC 50 60Hz Power rating 25...

Page 11: ...t will move to a factory pre set home position When the internal zero and home positions are being sought the alarm output flashes slowly When searching has been completed the closed gate closed outpu...

Page 12: ...e three ways to reset the unit to normal operation New impulse from pulse transmitter Reset from option reception push buttons via depressing both buttons simultaneously If these resets do not happen...

Page 13: ...teel brass or painted finishes can be supplied to special order please consult Gunnebo for further information Flexibility of Design The integrated design makes the GlasStile GSS simple to install wit...

Page 14: ...14 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Standard Dimensions Fig 4 1 Standard GlasStile GSS Dimensions...

Page 15: ...15 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Component Location Fig 4 2 Main Component Identification...

Page 16: ...or the various units Concrete to BS 5328 1997 specifications Type ST5 The base must be flat and level to 5mm over the GlasStile GSS area The base must be laid with under floor conduits with a minimum...

Page 17: ...e laid according to the specification indicated before installation begins All Electrical work MUST be carried out by a qualified engineer 1 Place the foundation plate and the centre column in the sel...

Page 18: ...on using the fixing screws 4 Fit the M4 x 8 Top Cladding Retaining screw into the chassis leaving approximately 2mm clearance between the head and surface 5 Insert the glazed panel making sure that th...

Page 19: ...lign the cladding edge profiles so that they interlock This is achieved by compressing the middle of the cladding and engaging the lock profile on the bottom edge 12 Slot the Retaining Strip into the...

Page 20: ...supply The power to the logic board motor and brake is supplied through a Toroidal transformer specification below Transformer wiring differences between 230Vac and 110Vac Suitable cables for connect...

Page 21: ...e 60mm 2 The power cable must be laid so that its sheath is secured in the clamp See Fig 5 7a 3 Connect the cores to the terminal block placed on one of the vertical bars see Fig 5 7 4 Ensure all conn...

Page 22: ...h length for the shielding to be fixed to the terminal 2 Secure the cable by its sheath in the clamp provided 3 Connect the shield to the terminal provided 4 Make all required connections ensure all c...

Page 23: ...Customer Connections Fig 5 7 Customer Connections Note The GlasStile should always have an independent fire signal If an echo signal is used the unit will not function correctly P7 Motor Connections P...

Page 24: ...ment purchase it is not supplied as part of the standard installation kit To program the GlasStile GSS the cladding must be moved The Hand Held Programmer is then connected to the serial port on the C...

Page 25: ...arch is now made Testing after Installation When the installation is complete test the system The GlasStile GSS will now search for a zero position INDEX 0 Do not interfere with the gate until this ha...

Page 26: ...ravel 90 O 3 13 rpm 1 15 seconds to travel 90 O 4 16 rpm 0 94 seconds to travel 90 O Hold Open Time TIME 1 0 8 second DF 2 1 6 second 3 4 seconds 4 8 seconds Acknowledgement Signal and Counter Impulse...

Page 27: ...l genciene trichlorethane Action Clean after with soap and water rinse well with clean water and wipe dry Rust and other Corrosion products Stainless Finishes Cleaning agent Oxalic acid The cleaning s...

Page 28: ...onditions increase the inspection intervals Warning To avoid the risk of electric shock always ensure that the electrical power is disconnected before inspecting the mechanism Lubricants For the lubri...

Page 29: ...t connections Restore the power supply Re set to normal functioning Replacing the Control Card Disconnect the power supplies Remove all connectors from the PCB If necessary remove the PCB supports Rec...

Page 30: ...30 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009...

Page 31: ...G42x40 40VDC 1 SE FU GS 0001 Fuse Q B 20mm 2 A 1 SM TR GS 0001 Transformer Toroidal 1 SM CB GS 0001 Timing Belt 2 5 x 80T 1 SE EL GS 0007 Electromagnetic Brake 1 SA MC MU 0008 Optical Sensor Assembly...

Page 32: ...32 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Section 8 Declaration of conformity Declaration of conformity...

Page 33: ...33 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Notes...

Page 34: ...UK Tel 44 0 1825 761022 Fax 44 0 1825 763835 E mail info entrancecontrol gunnebo com Web www gunnebo com A COMPANY WITHIN THE GUNNEBO GROUP HEAD OFFICE SWEDEN Gunnebo AB Box 5181 SE 402 26 Goteborg S...

Reviews: