Section 1

 

Introduction

 

 

Introduction 

 

 

 

 

 

 

 

 

 

 

 
General 

 
Please  read  this  manual  carefully,  it  contains  information  that  will  assist  you  with  all  aspects  of 
installation  and  maintenance,  including  unpacking.  Correct  installation  &  Maintenance  will  ensure 
smooth functionality and increase the lifespan of components. 
 
Gunnebo  Entrance  Control  Ltd  makes  every  effort  to  ensure  that  this  manual  is  reviewed  whenever 
significant  changes  are  made  to  the  design.    However,  our  policy  of  continuous  improvement  may 
result in some small differences between the unit supplied and the description in this document.  
 
Enquiries in this respect should, in the first instance, be directed to our Technical Department. 

Tel44 (0) 1825 746105, Fax +44 (0) 1825 763835, or alternatively E-mail 
turnsupport.entrancecontrol@gunnebo.com 

 

Electrical Warnings 

 
The  electrical  power  used  in  this  equipment  is  at  a  voltage  high  enough  to  endanger  life.    Before 
carrying out maintenance or repair, you must ensure that the equipment is isolated from the electrical 
supply and tests made to verify that the isolation is complete. 
 
When the supply cannot be disconnected, functional testing, maintenance and repair of the electrical 
units  is  to  be  undertaken  only  by  persons  fully  aware  of  the  danger  involved  and  who  have  taken 
adequate precautions and training. 

 
Mechanical Warnings 

 

Safety systems and controls, such as interlocks, covers and guards, must not be overridden or by 
passed by personnel other than authorised staff who are qualified to carry out prescribed   actions 
within specified Warnings.  
 
Only trained individuals should work on the unit as it has many moving parts and there is a possibility 
of serious injury

 

 
Errors 

 
Reports on errors, comments and suggestions concerning this manual are requested and encouraged.  
They should be submitted to: 
Technical  Department,  Gunnebo  Entrance  Control  Ltd,  Bellbrook  Business  Park,  Uckfield,  East 
Sussex, TN22 1QQ, UK. 
Tel44 (0)1825 746105, Fax +44 (0)1825 763835 or alternatively E-mail 
turnsupport.entrancecontrol@gunnebo.com 
 

Proprietary Notices 
 

All  data  appearing  herein  is  of  a  proprietary  nature,  with  exclusive  title  to  it  held  by  Gunnebo.  The 
possession of this Manual and the use of the information are therefore restricted only to those persons 
duly authorised by Gunnebo. 
 
Do  not  reproduce,  transcribe,  store  in  a  retrieval  system  or  translate  into  any  human  or  computer 
language, any part of this Manual without prior permission of Gunnebo. 
 

Hardware Changes 
 

No  hardware  changes  may  be  made  without  authority  from  Gunnebo  who  will  be  responsible  for 
ensuring  that  the  proposed  change  is  acceptable  in  all  safety  aspects.    Personnel  authorised  by 
Gunnebo may only make hardware changes. 
                                                                            

Summary of Contents for GlasStile GSS

Page 1: ...CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 GlasStile GSS Installation Operation and Maintenance Manual...

Page 2: ...CCEC OM Manual GlasStile GSS 1 6 EN 07 2009...

Page 3: ...the GlasStile GSS 11 Reception Control Pass Left Right Option 11 Operating Modes 12 Reset 12 Remote Push Button Activation Optional 12 Safety 12 Blocking the GlasStile GSS 12 Power Failure 12 Fire Ala...

Page 4: ...EN 07 2009 SECTION 6 MAINTENANCE 27 General Care 27 Brake Adjustment 29 Encoder Replacement 29 Replacing the Control Card 29 Trouble Shooting 29 SECTION 7 SPARE PARTS 31 Recommended Spare Parts 31 SEC...

Page 5: ...s fully aware of the danger involved and who have taken adequate precautions and training Mechanical Warnings Safety systems and controls such as interlocks covers and guards must not be overridden or...

Page 6: ...Warnings must be followed precisely They are given to avoid injury or death Cautions Are for conditions that may cause damage to equipment or may spoil work The instructions given in Cautions must be...

Page 7: ...ioning 8 Floor Drilling Glass Panel Installation Rating 1 Cleaning Who is at Risk Engineers or Site Personnel Hazard Mis use of Cleaning Fluids Current Controls Compliance with COSSH regulations Ratin...

Page 8: ...ontrols Protective Equipment must be worn Glass Panel Installation Who is at Risk Installation Engineer Hazard Glass Breaking Incorrect handling techniques Current Controls Protective Equipment must b...

Page 9: ...econds can be connected to the gate An acknowledgement impulse of completed rotations is given before or after each rotation is started complete The status of the gate is indicated on its volt free al...

Page 10: ...nical parts 304 grade Stainless Steel Glass Wing 10mm Toughened Glass Power Failure Gate Rotates freely with any power loss or emergency signal Power Supply Voltage 110 230 VAC 50 60Hz Power rating 25...

Page 11: ...t will move to a factory pre set home position When the internal zero and home positions are being sought the alarm output flashes slowly When searching has been completed the closed gate closed outpu...

Page 12: ...e three ways to reset the unit to normal operation New impulse from pulse transmitter Reset from option reception push buttons via depressing both buttons simultaneously If these resets do not happen...

Page 13: ...teel brass or painted finishes can be supplied to special order please consult Gunnebo for further information Flexibility of Design The integrated design makes the GlasStile GSS simple to install wit...

Page 14: ...14 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Standard Dimensions Fig 4 1 Standard GlasStile GSS Dimensions...

Page 15: ...15 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Component Location Fig 4 2 Main Component Identification...

Page 16: ...or the various units Concrete to BS 5328 1997 specifications Type ST5 The base must be flat and level to 5mm over the GlasStile GSS area The base must be laid with under floor conduits with a minimum...

Page 17: ...e laid according to the specification indicated before installation begins All Electrical work MUST be carried out by a qualified engineer 1 Place the foundation plate and the centre column in the sel...

Page 18: ...on using the fixing screws 4 Fit the M4 x 8 Top Cladding Retaining screw into the chassis leaving approximately 2mm clearance between the head and surface 5 Insert the glazed panel making sure that th...

Page 19: ...lign the cladding edge profiles so that they interlock This is achieved by compressing the middle of the cladding and engaging the lock profile on the bottom edge 12 Slot the Retaining Strip into the...

Page 20: ...supply The power to the logic board motor and brake is supplied through a Toroidal transformer specification below Transformer wiring differences between 230Vac and 110Vac Suitable cables for connect...

Page 21: ...e 60mm 2 The power cable must be laid so that its sheath is secured in the clamp See Fig 5 7a 3 Connect the cores to the terminal block placed on one of the vertical bars see Fig 5 7 4 Ensure all conn...

Page 22: ...h length for the shielding to be fixed to the terminal 2 Secure the cable by its sheath in the clamp provided 3 Connect the shield to the terminal provided 4 Make all required connections ensure all c...

Page 23: ...Customer Connections Fig 5 7 Customer Connections Note The GlasStile should always have an independent fire signal If an echo signal is used the unit will not function correctly P7 Motor Connections P...

Page 24: ...ment purchase it is not supplied as part of the standard installation kit To program the GlasStile GSS the cladding must be moved The Hand Held Programmer is then connected to the serial port on the C...

Page 25: ...arch is now made Testing after Installation When the installation is complete test the system The GlasStile GSS will now search for a zero position INDEX 0 Do not interfere with the gate until this ha...

Page 26: ...ravel 90 O 3 13 rpm 1 15 seconds to travel 90 O 4 16 rpm 0 94 seconds to travel 90 O Hold Open Time TIME 1 0 8 second DF 2 1 6 second 3 4 seconds 4 8 seconds Acknowledgement Signal and Counter Impulse...

Page 27: ...l genciene trichlorethane Action Clean after with soap and water rinse well with clean water and wipe dry Rust and other Corrosion products Stainless Finishes Cleaning agent Oxalic acid The cleaning s...

Page 28: ...onditions increase the inspection intervals Warning To avoid the risk of electric shock always ensure that the electrical power is disconnected before inspecting the mechanism Lubricants For the lubri...

Page 29: ...t connections Restore the power supply Re set to normal functioning Replacing the Control Card Disconnect the power supplies Remove all connectors from the PCB If necessary remove the PCB supports Rec...

Page 30: ...30 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009...

Page 31: ...G42x40 40VDC 1 SE FU GS 0001 Fuse Q B 20mm 2 A 1 SM TR GS 0001 Transformer Toroidal 1 SM CB GS 0001 Timing Belt 2 5 x 80T 1 SE EL GS 0007 Electromagnetic Brake 1 SA MC MU 0008 Optical Sensor Assembly...

Page 32: ...32 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Section 8 Declaration of conformity Declaration of conformity...

Page 33: ...33 CCEC OM Manual GlasStile GSS 1 6 EN 07 2009 Notes...

Page 34: ...UK Tel 44 0 1825 761022 Fax 44 0 1825 763835 E mail info entrancecontrol gunnebo com Web www gunnebo com A COMPANY WITHIN THE GUNNEBO GROUP HEAD OFFICE SWEDEN Gunnebo AB Box 5181 SE 402 26 Goteborg S...

Reviews: