background image

Günter & Hauer 

 

 

The hood is connected to the mains with a voltage of 220-240 V ~, 50 Hz. To avoid 
electric shock, the hood must be plugged into a grounded socket. This product belongs 
to class 1 protection against electric shock. Do not use light bulbs whose power rating 
exceeds  that  specified  in  the  hood  specifications,  as  bulbs  with  higher  wattages  can 
cause  various  damage  to  the  electrical  circuit.  Operation  of  the  hood  without  an 
aluminium grease trap is prohibited. When using the hood at the same time with other 
heating  devices  (gas,  oil,  coal  stoves,  etc.),  in  addition  to  electric,  you  may  need 
additional ventilation. 
Air passing through the hood and released into the atmosphere should only be vented to 
a separate kitchen ventilation shaft and should not enter the chimney or other duct used 
to remove smoke from other devices. 

When installing the hood to remove air into the ventilation shaft, do not use an air duct 
with  a  smaller  diameter  than  specified  in  the  operating  instructions.  This  can  create 
additional  resistance  to  the  exhaust  air  and  increase  noise  and  vibration,  as  well  as 
overheating of the engine. 

The hood must be installed above the electric  hobs at a height of at least 65 cm, and 
above the gas burners - at least 75 cm. 

Switch off the  mains voltage before carrying out any operation to clean or repair  the 
hood. 

According to these instructions, ensure timely washing of reusable aluminium grease 
traps. Unwashed filters reduce the efficiency of the hood and can cause a fire due to the 
accumulation of oil and dust. 

Do not sterilize food with an open flame directly under the hood. This can ignite the 
crude aluminium grease trap. 

Do not leave hot oil inside the pan on the stove. Overheated fat and oil ignite easily, 
which can cause the ignition of the crude aluminium grease trap. The flame of the gas 
burners must always be covered with utensils. Strong heat from the flame of gas burners 
can damage the hood. 

Do not turn on the hood to reduce smoke caused by an outbreak in the apartment. The 
included extractor will create additional draft for fire. In case of any ignition, disconnect 
the hood from the mains, cover the flame with a dense material that will prevent access 
of oxygen to the flame; never use water for extinguishing. 

 

 

Summary of Contents for MARTA 60

Page 1: ...G nter Hauer INSTRUCTION MANUAL COOKER HOOD MARTA 60...

Page 2: ...G nter Hauer CONTENT PRECAUTIONS 2 SIZE APPEARANCE 4 INSTALLATION CONNECTION 6 CONTROL PANEL 9 MAINTENANCE 10 TROUBLESHOOTING 12 SPECIFICATIONS 13...

Page 3: ...protective film from the stainless steel hood until you are sure about the technical serviceability of the hood by connecting it to the mains and checking all its functions We recommend that all work...

Page 4: ...ce to the exhaust air and increase noise and vibration as well as overheating of the engine The hood must be installed above the electric hobs at a height of at least 65 cm and above the gas burners a...

Page 5: ...rials used for packaging are environmentally safe and 100 recyclable as indicated by the appropriate symbol WARNING Packaging materials plastic bags pieces of foam etc should be inaccessible to childr...

Page 6: ...installation of the hood For a description of how to remove them see the relevant sections Check that there are no objects inside the hood placed during its transportation e g bags with screws instru...

Page 7: ...rap is positioned horizontally to avoid the accumulation of fat on one side INSTALLATION CONNECTION 1 Draw a vertical line on the wall to the ceiling or to the required height marking the centre of th...

Page 8: ...il it is securely fastened to the bracket INSTALLATION OF AIR DUCT Caution To reduce the risk of fire use only a metal air duct 1 Install the duct adapter on the hood 2 Put the air duct of the require...

Page 9: ...on the duct adapter 5 Install the ceiling wall cover Connect the air duct to it Use adhesive tape to connect the duct parts together Air recirculation mode Caution Do not use plastic or rigid air duct...

Page 10: ...it through the additional automatic switch 6A 3 Before installation of decorative boxes of an air duct deduce a wire for connection of the hood to the power supply network INSTALLATION OF TELESCOPIC P...

Page 11: ...aken within the next 3 seconds FILTER CONTAMINATION INDICATOR After a while using the hood the indicator will appear on the display This means that the hood filter is dirty and needs cleaning After cl...

Page 12: ...tructions below You can remove two panels from the hood Press the bottom panel inwards until you hear the lock clicking Lift and pull out the glass Similarly click on the middle panel until it clicks...

Page 13: ...electrical connection Check the fan setting Low hood efficiency The fan speed is not high enough Check the condition of the grease filter wash once every 1 5 2 months charcoal carbon filter may need...

Page 14: ...be disposed of separately from household waste in accordance with local regulations You will help to avoid negative consequences for the environment and human health which can be caused by improper re...