Recommended twisted pair cables
8
· G&D ControlCenter-Compact
Recommended twisted pair cables
The transmission of all signals of the
ControlCenter-Compact
system is carried out
through one twisted pair cable (category 5e or better).
The data transmission is reliable over a distance of at least 80 metres using a regular
standard twisted pair cable (category 5e or better).
The distance that can actually be bridged depends on the quality of the applied
cable. High-quality S-STP cables with an AWG22 wire gauge coding can bridge a
distance of up to 140 metres.
Patch cables with an AWG26 wire gauge coding can only bridge a maximum of 80
metres.
In order to ensure a reliable operation even in environments with interferences,
installation cables with at least AWG24 coding have to be used for lengths over 80
metres:
The following cables achieved the best results during test operation:
NOTE:
It is permitted to connect several segments of a cable connection with patch
panels and connection ports. It is, however, not permitted to connect active com-
ponents such as network switches, hubs or repeaters are not permitted.
Wire gauge
Cable type
Category
Recommendation
AWG22
Installation
5e, 6 or 7
up to 140 m
AWG24
Installation
5e, 6 or 7
up to 120 m
AWG26/27
Patch cable
5e, 6 or 7
up 80 m
NOTE:
The lengths that are mentioned in the table above must be interpreted as the
sum of all segments between the devices.
up to 80 meters:
Dätwyler uninet® 7702 flex
Patch cable
up to 100 meters:
Dätwyler uninet® 5502 AWG24 S-STP
Installationcable with sockets
up to 140 meters:
Kerpen MegaLine® G12-150 S/F AWG22
Installation cable with sockets
Dätwyler uninet® 7702 AWG 22
Installation cables with sockets