background image

Guntermann & Drunck GmbH 

Operating Instructions UserCenter 2 (4)

 

 

Page 11

 

 

6.10 

Time-out for automatic switch 

 
With this setting the time-out for the automatic switch between the local and the 
remote console is defined. 
 
To change the time-out for the automatic switch proceed as follows: 
 
Call up the setup mode with 

CTRL

 + 

BACKSPACE

 

 
You can choose between the following values of time-out: 

 
Time-out Key 

10 sec. 

F 5 

15 sec. 

F 6 

20 sec. 

F 7 

30 sec. 

F 8 

45 sec. 

F 9 

60 sec. 

F 10 

90 sec. 

F 11 

  1 sec. 

F 12 

 
After selecting the time-out value the setup mode will be closed automatically. 
The keyboard LEDs stop flashing. 
 
You can always stop the entry by pressing 

ESC

6.11 

Automatic mouse-enable (standard mouse driver) 

 
With this setting you define whether the mouse emulation sends data to the 
computer even if the computer has not given an enable. This only works with a 
standard mouse. 
 
For enabling the automatic mouse-enable proceed as follows: 

 

Call up the setup mode with 

CTRL

 + 

BACKSPACE

 

The setup mode will be indicated by the flashing of the three keyboard 
(NUM-Lock, CAPS-Lock, SCROLL-Lock). 

 

For enabling press 

Q

 

 To 

disable

 the mouse-enable again press 

W

 

 
After enabling/disabling the automatic mouse-enable the setup mode will be 
closed automatically. The three keyboard LEDs stop flashing.  
 
You can always stop the entry by pressing 

ESC

Summary of Contents for UserCenter 2

Page 1: ...UserCenter2 4 Operating Instructions Copyright G D 20 06 2006 M 6 50 S 5 60 Errors and technical changes excepted ...

Page 2: ...the default condition 7 6 3 Changing the keyboard scan code 7 6 4 Manual hold function 8 6 5 GET function 8 6 6 Darkening of a screen if the hold function is enabled 9 6 7 Transmission of GDFrames 9 6 8 Defining the double hotkey 10 6 9 Setting the HotKeys 10 6 10 Time out for automatic switch 11 6 11 Automatic mouse enable standard mouse driver 11 6 12 Automatic mouse reset 12 6 13 Support for th...

Page 3: ...PPLY CABLES ONLY USE ORIGINAL G D CABLES DAMAGES WHICH SOURCE FROM THE USE OF FOREIGN CABLES ARE NOT INCLUDED IN THE WARRANTY REGULATIONS AVOID TRUMPLE TRAPS WHEN LAYING THE CABLES VENTING SLOTS VENTING SLOTS PREVENT AN OVEHREATING OF THIS DEVICE DO NOT COVER THEM EXCLUSION OF WARRANTY G D DOES NOT TAKE OVER ANY WARRANTY FOR DEVICES WHICH WERE NOT USED ACCORDINGLY WERE REPAIRED OR MODIFIED BY NON ...

Page 4: ...ocal area and at a distance of up to 10 meters 2 Scope of Delivery 1 x UserCenter 2 UserCenter 4 PC Set 20 PowerSet 9 1 7 Manual 3 Installation Computer installation Disconnect monitor keyboard and mouse connecting cables from the computer Keyboard mouse Now connect both PS 2 connectors of the KM Y module cables to the keyboard and mouse interface of PC 1 Both connectors have corresponding symbols...

Page 5: ...r USER 1 2 PC Active Status Once it has been switched on the UserCenter initializes the connected keyboards and mice The User s green status LEDs light up and the LEDs on the keyboard flash At the same time User 1 s yellow active LED lights up When the PC is switched on the green PC status LED lights up and the other user s active LEDs are switched on Should one of the workstations access the comp...

Page 6: ... can be afforded to every workstation 5 1 Switching The UserCenter 2 4 allows the selectable operation of the computer from 2 4 consoles In default both keyboards and mice are enabled As soon as at one of the consoles there is keyboard or mouse action keyboard and mouse of the other station are disabled After a time out of approx 1 second where there is no action the system is enabled again The ti...

Page 7: ...d as described in chapter 6 4 5 3 GET function The GET Function allows that either the local or the remote work station can use the computer exclusivly In the initial state of the GET Function each connecetd consoles are blocked no keyboard and mouse action possible Additionaly if the dark switching mode has been activated compare chapter 6 6 all monitors are dark switched By triggering the keybor...

Page 8: ...tion will be released Default The dark switching is disabled If you wish to enable the dark switching proceed as described in chapter 6 6 5 5 Dark Switching of the screen whilst GET function Another type of the dark switching function is the result of a combination with the GET function Basiclly the dark switching of the screen whilst GET function corresponds to the function as described in chapte...

Page 9: ...me out for automatic switch local remote Automatic mouse enable Automatic mouse reset Support for the serial Logitech mouse Mouse enable Mouse reset The settings can be done via keyboard Mouse action during this procedure is not possible The following chapters describe how these settings are activated 6 1 Default Settings In default UserCenter 2 4 has the following settings Keyboard scan code 2 Ho...

Page 10: ...anging the keyboard scan code A change of this setting should only be done as agreed with the G D service With this setting the scan code for intializing the keyboard is defined To change the keyboard scan code proceed as follows Call up the setup mode with CTRL BACKSPACE The setup mode will be indicated by the flashing of the three keyboard LEDs NUM Lock CAPS Lock SCROLL Lock For scan code 2 pres...

Page 11: ...atically The keyboard LEDs stop flashing You can always stop the entry by pressing ESC 6 5 GET function With this setting you define whether the GET function will be activated or not For activating the GET function proceed as follows Call up the setup mode with CTRL BACKSPACE The setup mode will be indicated by the flashing of the three keyboard LEDs NUM Lock CAPS Lock SCROLL Lock angezeigt For en...

Page 12: ... the darkening is enabled disabled the setup mode will be closed automatically The keyboard LEDs stop flashing This setting has direct influence on the manual and automatic hold function see chapters 6 4 and 6 5 You can always stop the entry by pressing ESC 6 7 Transmission of GDFrames A change of this setting should only be done as agreed with the G D service For transmitting GDFrames proceed as ...

Page 13: ...ceed as follows Call up the setup mode with STRG BACKSPACE The setup mode will be indicated by the flashing of the three keyboard LEDs NUM Lock CAPS Lock SCROLL Lock The following keys are available Hotkey Combination Will be activated by Ctrl Shift Ctrl Alt Shift Alt Alt Gr Ctrl Alt Gr Windows Ctrl Windows Shift Windows Shift Note The terms in brackets are only relevant for the double hotkeys Aft...

Page 14: ...matically The keyboard LEDs stop flashing You can always stop the entry by pressing ESC 6 11 Automatic mouse enable standard mouse driver With this setting you define whether the mouse emulation sends data to the computer even if the computer has not given an enable This only works with a standard mouse For enabling the automatic mouse enable proceed as follows Call up the setup mode with CTRL BAC...

Page 15: ...nabling disabling the automatic mouse reset the setup mode will be closed automatically The keyboard LEDs stop flashing You can always stop the entry by pressing ESC 6 13 Support for the serial Logitech mouse With this setting you define whether to connect a Logitech or an Intelli mouse to the serial interface V 24 For supporting the serial mouse proceed as follows Call up the setup mode with CTRL...

Page 16: ...ual mouse enable the setup mode will be closed automatically The keyboard LEDs stop flashing You can always stop the entry by pressing ESC 6 15 Mouse reset manually Choose FUNCTION on your Windows operating system Independend from the selected mouse driver This is for WIN 98 WIN NT WIN ME WIN 2000 WIN XP With this function a manual mouse reset can be set For the manual mouse reset proceed as follo...

Page 17: ... supply 100 240 V primary 47 63 Hz Housing Desk top casing 210 x 44 x 211 UserCenter2 W x H x D 270 x 44 x 211 UserCenter 4 Transmission length Local area up to approx 10 m Options Remote operation over a distance of up to 250 meters in combination with video keyboard and mouse extension VKM system CATVision system Combination with miniMUX 2 4 CC1 plus CC4 for alternating operation of up to 96 PC ...

Page 18: ...able B Disable 6 6 Transmission of GDFrames G Enable H Disable 6 7 Defining the double hotkeys A activate S disable 6 8 Setting the hotkeys CTRL CTRL SHIFT ALT ALT SHIFT ALT GR ALT GR CTRL WINDOWS WINDOWS CTRL SHIFT SHIFT WINDOWS 6 9 Time out for automatic switch F5 10 seconds F6 15 seconds F7 20 seconds F8 30 seconds F9 45 seconds F10 60 seconds F11 90 seconds F12 1 seconds 6 10 Automatic mouse e...

Page 19: ...Guntermann Drunck GmbH Operating Instructions UserCenter 2 4 Page 16 8 2 Key Seizure SETUP Mode ...

Page 20: ... SGI DEC Alpha Station sind eingetragene Warenzeichen der jeweiligen Hersteller Guntermann Drunck GmbH Systementwicklung Dortmunder Str 4a 57234 Wilnsdorf Tel 02739 89010 Fax 02739 890120 Email sales GDsys de http www GDsys de ...

Reviews: