10. SPECIFICATIONS
10.1 TYPE APPROVAL
Vatette Water Leak Guard: SC0056-15
Vatette Clamping Ring Connector 0995/74
Vatette Water Leak Guard: SINTEF 20544
Vatette Water Leak Guard with water sensor: SINTEF 20570
10.2 ELECTRIC POWER
230 V for 24 V DC adapter
10.3 HEATING, VENTILATION AND SANITATION
Pressure class: PN10
Dimensions: 136 mm
¾" connector and Vatette end 22 mm
Motorised ball valve with manual override.
Max. working temperature: 60°C
Flow sensor: >0.3 litre/min
Pressure sensor: 0–16 bar
Noise level: Does not exceed 70 dB
9. SETTINGS
9.1 BASIC SETTINGS
To change settings such as the date, time and menu language, use the options in the Menu tree.
See MENU TREE pages 20 and 22.
9.2 PARAMETER SETTINGS
No parameter settings need to be changed for normal operation. If, for whatever reason, you
do change any of the parameter settings, it is important to check possible consequences on the
functionality of the water leak guard.
When changing parameter settings, you will need to enter code 1234 to access the system.
9.3 OTHER SETTINGS
If necessary, you can use the Menu tree to enter various other settings and choices.
See MENU TREE page 19–22.
Contact Villeroy & Boch Gustavsberg if you have any questions.
SC0056-15, 0995/74
1002
CERTIFIERING
KONTROLL
90
115
33
72
G3/4
DY22
G1
136
100
110
FLOW DIRECTION
18 (23)
Summary of Contents for VATETTE
Page 5: ...5 23 SVENSKA ...
Page 27: ...5 23 ENGLISH ...
Page 49: ...NORSK 5 23 ...
Page 71: ...DANSK 5 23 ...
Page 93: ...5 23 SUOMI ...
Page 111: ......