en
21
Activated Carbon Filter /
Maintenance
Precautions
Warning! Excessively greasy filters
represent the fire hazard! Fry below the
hood with the utmost caution!
Clean regularly! The metal filter should
be cleaned at least every two weeks.
The activated carbon filter must be re-
generated every 2-3 months. The re-
generation must be done in a normal
furnace at a temperature of 200 ° C, for
about 1-2 hours, depending on the
quantity of residues and the filter usage
time.
Warning! The auto-ignition threshold is
around 300-350 ° C!
Warning! Never use the oven pyrolysis
function! Never use temperatures
above 200 ° C! Danger of fire! Do not
cook on the flame under the hood! The
activated carbon filters must be re-
placed after 3-4 years of use.
These filters can be purchased at an
advantageous price at the company
GUTMANN itself, within its recycling
program.
Description of the filter functions
The activated carbon filters GUTMANN
are characterized by high regenerability
in traditional ovens and by durability. It
is also worth mentioning that their effi-
cacy 12 times superior to that of tradi-
tional carbon filters, and their noise is
minimum compared to other filters,
thanks to the honeycomb lamellar
structure. The absorbency capacity of
the GUTMANN activated carbon filters
is also due to a surface larger than the
other filters.
Regeneration
Regeneration takes place in a pre-
heated oven (200 ° C) and it lasts for 1-
2 hours depending on the level of dirt
accumulated on the filter.
Caution: Danger of fire!
Remove the filter from the oven only
after complete cooling.
This process can cause unpleasant
odors in the oven!
Caution:
- Do not regenerate the filter in the mi-
crowave oven!
- Never use the oven pyrolysis function
to regenerate the filter.
- Before regenerating the activated car-
bon filter, wash it with a damp cloth.
The need to regenerate the activated
carbon filter depends on the fre-
quency of cooking! However, you
should perform it at least every 2-3
months. Washing the activated carbon
filter with a damp cloth every 1-2
months is also recommended. The
high absorption capacity of the Gut-
mann carbon filter is best ensured
when the aspiration mode 2 is se-
lected.
Summary of Contents for Amplia 5300
Page 20: ...en 20 Removing the filtergitter Art Nr 3641 ab 07 2016 ...
Page 31: ...fr 31 Art Nr 3641 ab 07 2016 Enlever le filtre gitter ...
Page 42: ...it 42 Art Nr 3641 ab 07 2016 Rimozione del filtrogitter ...
Page 53: ...es 53 Art Nr 3641 ab 07 2016 Extracción del filtro gitter ...
Page 64: ...nl 64 Art Nr 3641 ab 07 2016 Filter verwijdering gitter ...
Page 77: ...de 9 600 Ansicht von oben 6 ABMESSUNG Ø 6 Ansicht von hinten Ansicht Turmhaltewinkel ...
Page 83: ......
Page 92: ...en 24 6 MEASUREMENTS 600 Ø 6 View from behind View from above ...
Page 98: ...en 30 ...
Page 106: ...fr 38 Vue du dessus 6 MESURES 600 Ø 6 ...
Page 111: ......
Page 121: ...it 53 6 MISURE Vista da sopra 600 Ø 6 ...
Page 127: ...it 59 ...
Page 135: ...es 67 6 MEDIDAS 600 Vista desde atrás Vista desde arriba Ø ...
Page 141: ......
Page 150: ...nl 82 600 Ø Achteraanzicht 6 AFMETINGEN Bovenaanzicht ...
Page 156: ...nl 88 ...
Page 158: ......
Page 159: ......